Determination of zinc in pharmaceutical products using an electrodialyser incorporated into a flow system

被引:0
|
作者
J. (Koos) F. van Staden
Cornelius J. Hattingh
机构
[1] Department of Chemistry,
[2] University of Pretoria,undefined
[3] Pretoria 0002,undefined
[4] South Africa e-mail: Koos.vanStaden@chem.up.ac.za,undefined
来源
Fresenius' Journal of Analytical Chemistry | 2000年 / 367卷
关键词
Zinc; Detection Limit; Flow System; Pharmaceutical Product; Flow Injection;
D O I
暂无
中图分类号
学科分类号
摘要
An electrodialyser unit has been designed, incorporated into the conduits of a flow injection (FI) system, and employed for the removal of interferences in the determination of zinc(II) in multivitamin tablets. The proposed system is fully computerised and is able to determine zinc(II) at a frequency of 18 samples/h with a sample interaction of 0.0015%. The calibration graph is linear between 1 and 20 mg/L. The detection limit is 0. 998 mg/L. The results obtained for zinc(II) in multivitamin tablets with the proposed system compared favourably with those obtained with the standard manual AAS method.
引用
收藏
页码:79 / 83
页数:4
相关论文
共 50 条
  • [1] Determination of bismuth in pharmaceutical products using liquid-liquid extraction in a flow injection system
    Alonso, A
    Almendral, MJ
    Báez, MD
    Porras, MJ
    Lávin, FL
    de María, CG
    ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) : 129 - 133
  • [2] Turbidimetric determination of homatropine methylbromide in pharmaceutical formulations using a flow injection analysis system
    Canaes, Larissa S.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2006, 29 (06): : 1237 - 1240
  • [3] Simple and selective method for determination of iodide in pharmaceutical products by flow injection analysis using the iodine–starch reaction
    D. Nacapricha
    K. Uraisin
    N. Ratanawimarnwong
    K. Grudpan
    Analytical and Bioanalytical Chemistry, 2004, 378 : 816 - 821
  • [4] Flow System with Electrochemical Detection for Determination of Paracetamol in Pharmaceutical Preparations
    Silva, M. L. S.
    Garcia, M. B. Q.
    Lima, J. L. F. C.
    Barrado, E.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2006, 24 (02) : 261 - 271
  • [5] Flow and sequential injection methods for the spectrofluorimetric determination of aluminium in pharmaceutical products using chromotropic acid as chromogenic reagent
    Themelis, DG
    Kika, FS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1179 - 1185
  • [6] Simple and selective method for determination of iodide in pharmaceutical products by flow injection analysis using the iodine-starch reaction
    Nacapricha, D
    Uraisin, K
    Ratanawimarnwong, N
    Grudpan, K
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) : 816 - 821
  • [7] Flow Injection Chemiluminescence Determination of Puerarin in Pharmaceutical Preparations Using Eosin Y-Fenton System
    Cai Zhuo
    Zhang Xian
    Lu Dengfeng
    Gan Jingni
    CHINESE JOURNAL OF CHEMISTRY, 2011, 29 (06) : 1261 - 1267
  • [8] Simultaneous determination of iron and zinc by pH gradient construction in a flow-injection system
    Zhao, SL
    Xia, XQ
    Yu, G
    Yang, B
    TALANTA, 1998, 46 (05) : 845 - 850
  • [9] Chemiluminescent determination of pyridoxine hydrochloride in pharmaceutical samples using flow injection
    Alwarthan, AA
    Aly, FA
    TALANTA, 1998, 45 (06) : 1131 - 1138
  • [10] FLOW-INJECTION DETERMINATION OF ZINC BY FLUORESCENCE SPECTROMETRY
    COMPANO, R
    HERNANDEZCASSOU, S
    PRAT, MD
    GARCIABELTRAN, L
    ANALYTICA CHIMICA ACTA, 1991, 255 (02) : 325 - 328