A simple and robust set-up for on-column sample preconcentration – nano-liquid chromatography – electrospray ionization mass spectrometry for the analysis of N-acylhomoserine lactones

被引:3
作者
Moritz Frommberger
Philippe Schmitt-Kopplin
Guichen Ping
Heinz Frisch
Michael Schmid
Yukui Zhang
Anton Hartmann
Antonius Kettrup
机构
[1] GSF National Research Center for Environment and Health,Institute of Ecological Chemistry
[2] GSF National Research Center for Environment and Health,Rhizosphere Biology Group, Institute of Soil Ecology
[3] Chinese Academy of Sciences,Dalian Institute of Chemical Physics
[4] Technische Universität München,Lehrstuhl für Ökologische Chemie und Umweltanalytik
来源
Analytical and Bioanalytical Chemistry | 2004年 / 378卷
关键词
Quorum sensing; AHL; Nano-HPLC; Sample preconcentration; Mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
A simple method for the simultaneous, rapid and sensitive determination of N-acylhomoserine lactone signaling molecules in bacterial isolates, without prior sample preconcentration and with minimal sample cleanup, is presented. The analysis relies on the combination of analyte preconcentration and separation on a single device: a relatively large sample volume (1–5 μL) is directly loaded onto a laboratory-made, miniaturized (75 μm i. d.) reverse phase nano-liquid chromatography column, connected on-line to a microelectrospray-ionization ion trap mass spectrometer. In a first step the analyte is adsorbed (and so concentrated) at the beginning of the column, and is eluted and selectively separated in a second step by the organic mobile phase. Sample preconcentration follows the mechanisms of solid phase extraction on a nano-scale, while separation takes place according to classical liquid chromatography separation principles. The columns can be manufactured easily, are simply connected, and used with minimal solvent amounts; this makes this method extremely robust and cost-effective. The analytical setup was found to be routinely quantitative down to a concentration of 10 ng/mL (corresponding to a total analyte amount of 10 pg or ca. 50 fmol). The limit of detection was reached at 1 ng/mL (1 pg, ca. 5 fmol). Compared to the classical AHL analysis of bacterial cultures with biosensors, where selectivity and sensitivity is often limited, this rapid analytical technique is a substantial qualitative and quantitative improvement. Two unsubstituted N-acylhomoserine lactones could be identified and quantified from a Burkholderia cepacia culture supernatant in a chloroform extract.
引用
收藏
页码:1014 / 1020
页数:6
相关论文
共 36 条
[1]  
Fuqua undefined(1994)undefined J Bacteriol 176 269-undefined
[2]  
Salmond undefined(1995)undefined Mol Microbiol 16 615-undefined
[3]  
Swift undefined(1996)undefined Trends Biochem Sci 21 214-undefined
[4]  
Miller undefined(2001)undefined Annu Rev Microbiol 55 165-undefined
[5]  
Eberl undefined(1999)undefined Syst Appl Microbiol 22 493-undefined
[6]  
Williams undefined(2000)undefined Philos Tr R Soc B 355 667-undefined
[7]  
Passador undefined(1993)undefined Science 260 1127-undefined
[8]  
Smith undefined(2003)undefined Curr Opin Microbiol 6 56-undefined
[9]  
Geisenberger undefined(2000)undefined FEMS Microbiol Lett 184 273-undefined
[10]  
Conway undefined(2002)undefined J Bacteriol 184 5678-undefined