Neural network-based image reconstruction in swept-source optical coherence tomography using undersampled spectral data

被引:0
作者
Yijie Zhang
Tairan Liu
Manmohan Singh
Ege Çetintaş
Yilin Luo
Yair Rivenson
Kirill V. Larin
Aydogan Ozcan
机构
[1] University of California,Electrical and Computer Engineering Department
[2] University of California,Department of Bioengineering
[3] University of California,California NanoSystems Institute
[4] University of Houston,Department of Biomedical Engineering
[5] University of Houston,Department of Molecular Physiology and Biophysics, Baylor College of Medicine
[6] University of California,Department of Surgery, David Geffen School of Medicine
来源
Light: Science & Applications | / 10卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Optical coherence tomography (OCT) is a widely used non-invasive biomedical imaging modality that can rapidly provide volumetric images of samples. Here, we present a deep learning-based image reconstruction framework that can generate swept-source OCT (SS-OCT) images using undersampled spectral data, without any spatial aliasing artifacts. This neural network-based image reconstruction does not require any hardware changes to the optical setup and can be easily integrated with existing swept-source or spectral-domain OCT systems to reduce the amount of raw spectral data to be acquired. To show the efficacy of this framework, we trained and blindly tested a deep neural network using mouse embryo samples imaged by an SS-OCT system. Using 2-fold undersampled spectral data (i.e., 640 spectral points per A-line), the trained neural network can blindly reconstruct 512 A-lines in 0.59 ms using multiple graphics-processing units (GPUs), removing spatial aliasing artifacts due to spectral undersampling, also presenting a very good match to the images of the same samples, reconstructed using the full spectral OCT data (i.e., 1280 spectral points per A-line). We also successfully demonstrate that this framework can be further extended to process 3× undersampled spectral data per A-line, with some performance degradation in the reconstructed image quality compared to 2× spectral undersampling. Furthermore, an A-line-optimized undersampling method is presented by jointly optimizing the spectral sampling locations and the corresponding image reconstruction network, which improved the overall imaging performance using less spectral data points per A-line compared to 2× or 3× spectral undersampling results. This deep learning-enabled image reconstruction approach can be broadly used in various forms of spectral-domain OCT systems, helping to increase their imaging speed without sacrificing image resolution and signal-to-noise ratio.
引用
收藏
相关论文
共 57 条
[1]  
Huang D(1991)Optical coherence tomography Science 254 1178-1181
[2]  
Fercher AF(1995)Measurement of intraocular distances by backscattering spectral interferometry Opt. Commun. 117 43-48
[3]  
Chinn SR(1997)Optical coherence tomography using a frequency-tunable optical source Opt. Lett. 22 340-342
[4]  
Swanson EA(2003)Sensitivity advantage of swept source and Fourier domain optical coherence tomography Opt. Express 11 2183-2189
[5]  
Fujimoto JG(2003)Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography Opt. Lett. 28 2067-2069
[6]  
Choma MA(2017)Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited] Biomed. Opt. Express 8 3248-3280
[7]  
De Boer JF(2006)Ultrahigh-speed optical frequency domain imaging and application to laser ablation monitoring Appl. Phys. Lett. 88 103902-3237
[8]  
De Boer JF(2006)Fourier Domain Mode Locking (FDML): a new laser operating regime and applications for optical coherence tomography Opt. Express 14 3225-2977
[9]  
Leitgeb R(2006)Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s Opt. Lett. 31 2975-1433
[10]  
Wojtkowski M(2006)Comprehensive volumetric optical microscopy in vivo Nat. Med. 12 1429-716