Venobronchial fistula: an unusual early complication after central venous catheterization

被引:0
作者
V. Guariento
G. B.Luciani
B. Dal Corso
A. Carletti
A. Mazzucco
A. Luzzani
机构
[1] University of Verona,Division of Anesthesiology
[2] University of Verona,Division of Cardiac Surgery
来源
Intensive Care Medicine | 1997年 / 23卷
关键词
Central venous catheterization; Venobronchial fistula; Cardiac surgery; Complications;
D O I
暂无
中图分类号
学科分类号
摘要
Venobronchial fistula is a rare complication of long-term central venous catheterization. We present the uncommon occurrence of a venobronchial fistula as an acute complication of central venous catheterization during open heart surgery. The factors responsible for this unusual complication and the methods to prevent it are discussed.
引用
收藏
页码:1176 / 1178
页数:2
相关论文
共 27 条
[1]  
Ismat F(1969)Bronchovenous fistula as a late complication of ventriculoatriostomy J Neurosurg 31 574-576
[2]  
Brennan MF(1973)Venobronchial fistula: a rare complication of central venous catheterization for parenteral hyperalimentation Arch Surg 106 871-872
[3]  
Sugarbaker PH(1982)Perforation pulmonaire: Complication inhabituelle d’ un catheterisme veineux central Presse Med 11 2714-2714
[4]  
Moore FD(1987)A rare complication of central venous catheterization J Parenter Enteral Nutr 11 580-582
[5]  
Edouard D(1987)Atriobronchial fistula: An unusual complication of intravenous feeding in the presence of a mediastinal abscess (Letter) Anaesthesia 42 669-670
[6]  
Boderau A-M(1990)Venobronchial fistula: a complication associated with central venous catheterization for chemotherapy Cathet Cardiovasc Diagn 19 49-52
[7]  
Langlois B(1991)Case report: Venobronchial fistula. An unusual chest radiograph presentation of a central venous line complication Clin Radiol 44 283-284
[8]  
Demey HE(1992)Unusual cause of hemoptysis. Hickman-induced cavabronchial fistula Chest 102 1285-1286
[9]  
Colemaont LJ(1991)In vitro evaluation of relative perforating potential of central venous catheters: comparison of materials, selected models, number of lumens and angles of incidence to simulated membrane J Clin Monit 7 1-6
[10]  
Hartoko TJ(undefined)undefined undefined undefined undefined-undefined