Monte carlo simulation of a radiation shielding carrier for proton-beam-irradiated sample

被引:0
|
作者
Se-Jin Ra
Myung-Hwan Jung
Kye-Ryung Kim
机构
[1] Korea Atomic Energy Research Institute,Proton Engineering Frontier Project
来源
Journal of the Korean Physical Society | 2013年 / 63卷
关键词
Monte Carlo simulation; Proton beam; Radiation shielding; Shield carrier;
D O I
暂无
中图分类号
学科分类号
摘要
Two target rooms, TR23 and TR103, will be constructed for the utilization of the 20-MeV and the 100-MeV linear proton beams, and hot cells will be installed at these target rooms to handle samples that are highly activated by proton beam bombardment. The sample transport methods depend on the sample size because of the limited size of the penetration hole between the target room and the treatment room. For small samples that can be transported through the penetration hole, we can use a remotely-operated sample transport system, but for large-size samples will have to be moved through the shielding door opening, so a lead-shielded carrier has to be used for radiation protection. The carrier can be used to transport the samples from hot cell to another radiation worker’s areas in the accelerator building. In this research, we designed a lead-shielded carrier and evaluated its radiation shielding capability for the expected samples and their radioactivities by using Monte Carlo code simulations. We also calculated the shielding capability of the hot cell.
引用
收藏
页码:1407 / 1413
页数:6
相关论文
共 50 条
  • [1] Monte carlo simulation of a radiation shielding carrier for proton-beam-irradiated sample
    Ra, Se-Jin
    Jung, Myung-Hwan
    Kim, Kye-Ryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1407 - 1413
  • [2] Application of Monte Carlo to proton beam radiation therapy
    Siebers, JV
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 1051 - 1056
  • [3] Monte Carlo simulation of a therapeutical proton beam line
    Russo, S
    Bucciolini, M
    Compagnucci, A
    Mazal, A
    Nauraye, C
    Rosenwald, JC
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (02): : 63 - 71
  • [4] CHARGE-INDUCED ABSORPTION IN PROTON-BEAM-IRRADIATED SOLID HYDROGEN DEUTERIDE
    MILLER, JJ
    BROOKS, RL
    HUNT, JL
    POLL, JD
    CANADIAN JOURNAL OF PHYSICS, 1988, 66 (11) : 1025 - 1030
  • [5] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Da-Eun Kwon
    Dong-Hee Han
    Kyung-Hwan Jung
    Seung-Jae Lee
    Jang-Oh Kim
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2023, 82 : 813 - 817
  • [6] A Study on Radiation Shielding Ability of Composite Materials Using Monte Carlo Simulation
    Cha, Ju-Hee
    Jeon, Han-Yong
    POLYMER-KOREA, 2019, 43 (05) : 798 - 806
  • [7] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Kwon, Da-Eun
    Han, Dong-Hee
    Jung, Kyung-Hwan
    Lee, Seung-Jae
    Kim, Jang-Oh
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 82 (08) : 813 - 817
  • [8] MULASSIS - Monte Carlo radiation shielding simulation for space applications made easy
    Truscott, P
    Lei, F
    Dyer, C
    Quaghebeur, B
    Heyndericks, D
    Nieminen, P
    Evans, H
    Daly, E
    Mohammadzadeh, A
    Hopkinson, G
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 191 - 196
  • [9] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [10] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Corp. Res. Proc. Technol. Laboratory, 3M Company, 3M Center, St. Paul, MN 55144-1000, United States
    不详
    不详
    Radiat. Phys. Chem., 5 (475-485):