Prevalence of mitral annular disjunction in patients with mitral valve prolapse and severe regurgitation

被引:0
作者
Andrew J. Putnam
Kalie Kebed
Victor Mor-Avi
Nina Rashedi
Deyu Sun
Brooke Patel
Husam Balkhy
Roberto M. Lang
Amit R. Patel
机构
[1] University of Chicago Medicine,Biological Sciences Division
[2] Philips Healthcare,undefined
来源
The International Journal of Cardiovascular Imaging | 2020年 / 36卷
关键词
Mitral annular disjunction; Mitral valve prolapse; Cardiac computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Mitral annular disjunction (MAD) is routinely diagnosed by cardiac imaging, mostly by echocardiography, and shown to be a risk factor for ventricular arrhythmias. While MAD is associated with mitral valve (MV) prolapse (MVP), it is unknown which patients with MAD are at higher risk and which additional imaging features may help identify them. The value of cardiac computed tomography (CCT) for the diagnosis of MAD is unknown. Accordingly, we aimed to: (1) develop a standardized CCT approach to identify MAD in patients with MVP and severe mitral regurgitation (MR); (2) determine its prevalence and identify features that are associated with MAD in this population. We retrospectively studied 90 patients (age 63 ± 12 years) with MVP and severe MR, who had pre-operative CCT (256-slice scanner) of sufficient quality for analysis. The presence and degree of MAD was assessed by rotating the view plane around the MV center to visualize disjunction along the annulus. Additionally, detailed measurements of MV apparatus and left heart chambers were performed. Univariate logistic regression analysis was performed to determine which parameters were associated with MAD. MAD was identified in 18 patients (20%), and it was typically located adjacent to a prolapsed or flail mitral leaflet scallop. Of these patients, 75% had maximum MAD distance > 4.8 mm and 90% > 3.8 mm. Female gender was most strongly associated with MAD (p = 0.04). Additionally, smaller end-diastolic mitral annulus area (p = 0.045) and longer posterior leaflet (p = 0.03) were associated with greater MAD. No association was seen between MAD and left ventricular size and function, left atrial size, and papillary muscle geometry. CCT can be used to readily detect MAD, by taking advantage of the 3D nature of this modality. A significant portion of MVP patients referred for mitral valve repair have MAD. The presence of MAD is associated with female gender, smaller annulus size and greater posterior leaflet length.
引用
收藏
页码:1363 / 1370
页数:7
相关论文
共 71 条
[1]  
Nishimura RA(1985)Echocardiographically documented mitral-valve prolapse. Long-term follow-up of 237 patients N Engl J Med 313 1305-1309
[2]  
McGoon MD(2015)Arrhythmic mitral valve prolapse and sudden cardiac death Circulation 132 556-566
[3]  
Shub C(2016)Bileaflet mitral valve prolapse and risk of ventricular dysrhythmias and death J Cardiovasc Electrophysiol 27 463-468
[4]  
Miller FA(2016)Morphofunctional abnormalities of mitral annulus and arrhythmic mitral valve prolapse Circ Cardiovasc Imaging 9 e005030-1022
[5]  
Ilstrup DM(2005)Mitral annular disjunction in advanced myxomatous mitral valve disease: echocardiographic detection and surgical correction J Am Soc Echocardiogr 18 1014-670
[6]  
Tajik AJ(1981)The conduction system in mitral valve prolapse syndrome with sudden death Am Heart J 101 667-1433
[7]  
Basso C(2017)Functional implication of mitral annular disjunction in mitral valve prolapse: a quantitative dynamic 3D echocardiographic study JACC Cardiovasc Imaging 10 1424-1436
[8]  
Perazzolo Marra M(2017)Mitral annular disjunction: the forgotten component of myxomatous mitral valve disease JACC Cardiovasc Imaging 10 1434-185
[9]  
Rizzo S(2017)The analysis of mitral annular disjunction detected by echocardiography and comparison with previously reported pathological data J Echocardiogr 15 176-1609
[10]  
Nordhues BD(2018)The mitral annulus disjunction arrhythmic syndrome J Am Coll Cardiol 72 1600-1552