The maze operation - Surgical therapy for chronic atrial fibrillation: Modification to the mini-maze procedure

被引:0
作者
Szalay Z.A. [1 ]
Skwara W. [1 ]
Pitschner H.F. [2 ]
Faude I. [2 ]
Klövekorn W.P. [1 ]
Bauer E.P. [1 ]
机构
[1] Abteilung Herzchirurgie, Kerckhoff-Klinik, D-61231 Bad Nauheim
[2] Abteilung Kardiologie, Kerckhoff-Klinik, D-61231 Bad Nauheim
来源
Zeitschrift für Kardiologie | 2000年 / 89卷 / Suppl 10期
关键词
Arrhythmia; Atrial fibrillation; Maze procedure;
D O I
10.1007/s003920070005
中图分类号
学科分类号
摘要
Summary Objective: Atrial fibrillation (AF) is the most common arrhythmia. However, its precise electrophysiologic mechanism is still not well understood. Chronic symptomatic atrial fibrillation resistant to medical therapy can successfully be treated by the Maze III procedure (M III). Several publications are dealing with alternative surgical techniques. This study describes technique and midterm results of a Mini-variant (Mini) of the Maze III procedure. Methods: During a 48-month period we performed either a M III (group I = 7 patients) or a Mini-Maze operation (group II = 65 patients) in 33 males and 39 females with chronic symptomatic atrial fibrillation and additional cardiac pathology. Patients were controlled 4.0 ± 1.8 months (group I) respectively 3.6 ± 0.8 months (group II) (NS) and 16.75 ± 2.5 months (group I) respectively 13.2 ± 1.9 months (group II) (NS) after operation by means of thorough electrophysiological assessment, right heart catheterization, MRI, echocardiography, stress-ECG and 24h-ECG. Results: There was no significant difference between the two groups with regard to sex, age and duration of AF. Echocardiographic left atrial diameter (LAD) was 75 ± 11 mm in group I and 65 ± 8 mm in group II (p = 0.002). Whereas right atrial diameter was 62 ± 8 mm in group I and 57 ± 7 mm in group II (NS). Perioperative data (n = 72): Aortic cross clamp time was 127 ± 40 min in group I and 87 ± 22 min in group II (p = 0.0002). Cardiopulmonary bypass time was 185 ± 71 min in group I and 137 ± 42 min in group II (p = 0.01). Postoperative data I (first follow-up: n = 66): sinus rhythm (yes): 4/7 vs. 47/59 (NS); pacemaker (PM) in AAI mode (yes): 1/7 vs. 3/59 (NS); inducible atrial fibrillation (yes): 2/7 vs. 5/59 (NS); Bradycardie Tachycardie Syndrome with the need of PM implantation 0/7 vs. 4/59 (NS). Postoperative data H (second followup: n = 55): sinus rhythm (yes): 5/7 vs. 34/48 (NS); PM in AAI mode (yes): 0/7 vs. 4/48 (NS); Inducible atrial fibrillation (yes): 2/7 vs. 5/48 (NS); Bradycardia Tachycardia Syndrome with the need of PM Implantation 0/7 vs. 5/48. Conclusion: Midterm results are identical after M III and Mini. The Mini-Maze procedure is less complex compared to the Maze III procedure and there is a significant reduction of crossclamp and ECC times. We recommend the Mini especially for polymorbid patients and for those with poor left ventricular function.
引用
收藏
页码:29 / 34
页数:5
相关论文
共 50 条
  • [31] Impact of maze procedure in patients with severe tricuspid regurgitation and persistent atrial fibrillation
    Park, Ilkun
    Jeong, Dong Seop
    Park, Sung-Ji
    Ahn, Joong Hyun
    Kim, Jihoon
    Kim, Eun Kyoung
    Sung, Kiick
    Kim, Wook Sung
    Park, Pyo Won
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 166 (02) : 478 - +
  • [32] Surgical Maze Procedure as a Treatment for Atrial Fibrillation: A Meta-Analysis of Randomized Controlled Trials
    Kong, Melissa H.
    Lopes, Renato D.
    Piccini, Jonathan P.
    Hasselblad, Vic
    Bahnson, Tristram D.
    Al-Khatib, Sana M.
    CARDIOVASCULAR THERAPEUTICS, 2010, 28 (05) : 311 - 326
  • [33] Normal Quality of Life After the Cox-Maze Procedure for Atrial Fibrillation
    Melby, Spencer J.
    Zierer, Andreas
    Lubahn, Jordon G.
    Bailey, Marci S.
    Cox, James L.
    Schuessler, Richard B.
    Damiano, Ralph J., Jr.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2008, 3 (03) : 142 - 146
  • [34] The maze operation for treatment of atrial fibrillation -: Early clinical experience in a Scandinavian institution
    Albåge, A
    van der Linden, J
    Lindblom, D
    Kennebäck, G
    Nygren, AT
    Svedenhag, J
    Bengtsson, L
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (05) : 480 - 485
  • [35] Incomplete ablation as a mechanism of atrial fibrillation recurrence and atrial tachycardia development after maze procedure
    Nitta, Takashi
    Iwasaki, Yuki
    Sakamoto, Shun-ichiro
    Fujii, Masahiro
    Otsuka, Toshiaki
    Ishii, Yosuke
    JTCVS OPEN, 2025, 23 : 110 - 119
  • [36] Preliminary results with the microwave-modified maze III procedure for the treatment of chronic atrial fibrillation
    Hurlé, A
    Ibáñez, A
    Parra, JM
    Martínez, JG
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (12): : 1644 - 1646
  • [37] Surgical Treatment for Isolated Atrial Fibrillation Minimally Invasive vs Classic Cut and Sew Maze
    Lee, Richard
    McCarthy, Patrick M.
    Passman, Rod S.
    Kruse, Jane
    Malaisrie, S. Chris
    Mcgee, Edwin C.
    Lapin, Brittany
    Jacobson, Jason T.
    Goldberger, Jeffrey
    Knight, Bradley P.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2011, 6 (06) : 373 - 377
  • [38] Ten year experience with the concomitant Maze IV procedure for atrial fibrillation
    Francois, Jules
    Claus, Isabelle
    Cathenis, Koen
    Francois, Bart
    Provenier, Frank
    Goossens, Dominique
    Ballaux, Philippe K. E. W.
    ACTA CHIRURGICA BELGICA, 2022, 122 (02) : 99 - 106
  • [39] Late outcomes after the Cox maze IV procedure for atrial fibrillation
    Henn, Matthew C.
    Lancaster, Timothy S.
    Miller, Jacob R.
    Sinn, Laurie A.
    Schuessler, Richard B.
    Moon, Marc R.
    Melby, Spencer J.
    Maniar, Hersh S.
    Damiano, Ralph J., Jr.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (05) : 1168 - +
  • [40] Electro cautery maze in chronic atrial fibrillation: An early experinece
    A Inamdar
    P Reddy
    S Inamdar
    V Gaikward
    Indian Journal of Thoracic and Cardiovascular Surgery, 2004, 20 (1) : 35 - 35