摘要
We reviewed a consecutive series of 19 patients with comminuted periprosthetic fractures, loosening of the femoral stem (Vancouver type B3) and significant loss of bone stock (Paprosky type III and IV). Sixteen porous-coated long stems and three Exeter stems, all with impaction grafting, were used. Large femoral onlay strut allografts were applied to maintain fracture reduction and improve stability. There was one early re-fracture at the tip of the femoral stem. Eighteen fractures healed without deformity and shortening. At the last follow-up at mean 3.7 (2.0–7.5) years, the mean Harris hip score was 76.4 (57.5–92.0). There was ingrowth of all strut grafts and significant augmentation of periprosthetic bone.
引用
收藏
页码:164 / 167
页数:3
相关论文
共 50 条
  • [1] Periprosthetic fractures with extensive bone loss treated with onlay strut allografts
    Barden, B
    von Knoch, M
    Fitzek, JG
    Löer, F
    INTERNATIONAL ORTHOPAEDICS, 2003, 27 (03) : 164 - 167
  • [2] Reconstruction of metadiaphyseal bone defects of the femur with cortical strut allografts in periprosthetic bone loss
    Orfanos, G.
    Ding, Y.
    Bode, C. P.
    Barden, B.
    Fitzek, J. G.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2014, 26 (02): : 162 - 170
  • [3] Metadiaphysäre Femurdefektrekonstruktion mit kortikalen Strut-Allografts bei periprothetischen KnochendefektenReconstruction of metadiaphyseal bone defects of the femur with cortical strut allografts in periprosthetic bone loss
    G. Orfanos
    Y. Ding
    C.P. Bode
    B. Barden
    J.G. Fitzek
    Operative Orthopädie und Traumatologie, 2014, 26 (2) : 162 - 170
  • [4] Strut allografts for failed treatment of periprosthetic femoral fractures -: Good outcome in 13 patients
    Barden, B
    Ding, Y
    Fitzek, JG
    Löer, F
    ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (02): : 146 - 153
  • [5] Treatment of Vancouver Type B Periprosthetic Femoral Fractures Using Cortical Strut Allografts
    Kwon, Dae Gyu
    Park, Jin Seong
    Moon, Kyoung Ho
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [6] Use of Locking Plate and Strut Onlay Allografts for Periprosthetic Fracture Around Well-Fixed Femoral Components
    Kim, Young-Hoo
    Mansukhani, Sameer Ajit
    Kim, Jun-Shik
    Park, Jang-Won
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 166 - 170
  • [7] Sandwiched Strut Allografts with Stem Retention to Treat Fragile Periprosthetic Femoral Fractures: A Case Report
    Kim, Hyoung Tae
    Lee, Hyun Jun
    Jo, Suenghwan
    MEDICINA-LITHUANIA, 2025, 61 (01):
  • [8] Combined use of extensively porous coated femoral components with onlay cortical strut allografts in revision of Vancouver B2 and B3 periprosthetic femoral fractures
    Wu Hao-bo
    Yan Shi-gui
    Wu Li-dong
    He Rong-xin
    Wang Xiang-hua
    Dai Xue-song
    CHINESE MEDICAL JOURNAL, 2009, 122 (21) : 2612 - 2615
  • [9] Combined use of extensively porous coated femoral components with onlay cortical strut allografts in revision of Vancouver B2 and B3 periprosthetic femoral fractures
    WU Haobo YAN Shigui WU Lidong HE Rongxin WANG Xianghua DAI Xuesong Department of Orthopeadic SurgerySecond Affiliated HospitalCollege of MedicineZhejiang UniversityHangzhouZhejiang China
    中华医学杂志(英文版), 2009, (21) : 2612 - 2615
  • [10] Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate
    Haddad, FS
    Duncan, CP
    Berry, DJ
    Lewallen, DG
    Gross, AE
    Chandler, HP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06): : 945 - 950