Radio-frequency thermal ablation of liver metastases with a cooled-tip electrode needle: results of a pilot clinical trial

被引:0
|
作者
R. Lencioni
O. Goletti
N. Armillotta
A. Paolicchi
M. Moretti
D. Cioni
F. Donati
A. Cicorelli
S. Ricci
M. Carrai
P. F. Conte
E. Cavina
C. Bartolozzi
机构
[1] Division of Diagnostic and Interventional Radiology,
[2] Department of Oncology,undefined
[3] University of Pisa,undefined
[4] Via Roma 67,undefined
[5] I-56 125 Pisa,undefined
[6] Italy,undefined
[7] Division of General and Emergency Surgery,undefined
[8] Department of Surgery,undefined
[9] University of Pisa,undefined
[10] Via Roma 67,undefined
[11] I-56 125 Pisa,undefined
[12] Italy,undefined
[13] Division of Medical Oncology,undefined
[14] Department of Oncology,undefined
[15] University of Pisa,undefined
[16] Via Roma 67,undefined
[17] I-56 125 Pisa,undefined
[18] Italy,undefined
[19] Division of Internal Medicine II,undefined
[20] Santa Chiara Hospital,undefined
[21] Via Roma 67,undefined
[22] I-56 125 Pisa,undefined
[23] Italy,undefined
来源
European Radiology | 1998年 / 8卷
关键词
Key words: Liver; Interventional procedure; Liver neoplasms; Therapy; Radio-frequency ablation;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate feasibility, safety, and effectiveness of radio-frequency (RF) thermal ablation, performed by using a cooled-tip electrode needle, in the treatment of liver metastases. Twenty-nine patients (20 males and 9 females; age range 43–77 years) with one to four hepatic metastases 1.1–4.8 cm in diameter (mean 2.9 ± 0.8 cm) from previously resected intra-abdominal primary malignancies were treated. All patients were excluded from surgery and had partial or no response to chemotherapy. Radio-frequency ablation was performed by using a 100-W generator and 17-gauge, dual-lumen, cooled-tip electrode needles with a 2- to 3-cm exposed tip. Exposure time was 12 min for each needle insertion. Findings at spiral CT were used to assess the therapeutic response. A total of 127 insertions were performed (mean 2.4 ± 1.7 insertions/lesion) during 84 treatment sessions (mean 1.6 ± 0.7 sessions/lesion) in absence of major complications. Complete tumor response (i. e., unenhancing area of thermal necrosis larger than the treated tumor) was seen in 41 (77 %) of 53 lesions, including 33 (87 %) of 38 lesions 3 cm or less in diameter. After a mean follow-up period of 6.5 ± 2.1 months (range 3–9 months), recurrence of the treated lesion was seen in 5 (12 %) of the 41 cases. New metastatic lesions appeared in 7 patients. Two patients died after 6 and 8 months, respectively. Of the 27 patients still in follow-up, 14 are currently free of disease. Radio-frequency thermal ablation with a cooled-tip electrode needle is a safe and effective local treatment for hepatic metastases 3 cm or less in greatest dimension.
引用
收藏
页码:1205 / 1211
页数:6
相关论文
共 20 条
  • [1] Radio-frequency thermal ablation of liver metastases with a cooled-tip electrode needle: results of a pilot clinical trial
    Lencioni, R
    Goletti, O
    Armillotta, N
    Paolicchi, A
    Moretti, M
    Cioni, D
    Donati, F
    Cicorelli, A
    Ricci, S
    Carrai, M
    Conte, PF
    Cavina, E
    Bartolozzi, C
    EUROPEAN RADIOLOGY, 1998, 8 (07) : 1205 - 1211
  • [2] Hepatic metastases: Percutaneous radio-frequency ablation with cooled-tip electrodes
    Solbiati, L
    Goldberg, SN
    Ierace, T
    Livraghi, T
    Meloni, F
    Dellanoce, M
    Sironi, S
    Gazelle, GS
    RADIOLOGY, 1997, 205 (02) : 367 - 373
  • [3] Open radio-frequency thermal ablation of renal VX2 tumors in a rabbit model using a cooled-tip electrode: feasibility, safety, and effectiveness
    Lee, JM
    Kim, SW
    Chung, GH
    Lee, SY
    Han, YM
    Kim, CS
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1324 - 1332
  • [4] Percutaneous treatment of liver tumors with an adapted probe for cooled-tip, impedance-controlled radio-frequency ablation under open-magnet MR guidance: initial results
    Kelekis, AD
    Terraz, S
    Roggan, A
    Terrier, FO
    Majno, P
    Mentha, G
    Roth, A
    Becker, CD
    EUROPEAN RADIOLOGY, 2003, 13 (05) : 1100 - 1105
  • [5] Percutaneous treatment of liver tumors with an adapted probe for cooled-tip, impedance-controlled radio-frequency ablation under open-magnet MR guidance: initial results
    Alexis D. Kelekis
    Sylvain Terraz
    André Roggan
    François Terrier
    Pietro Majno
    Gilles Mentha
    Arnaud Roth
    Christoph D. Becker
    European Radiology, 2003, 13 : 1100 - 1105
  • [6] Microwave Ablation: The Differences Between Biliary Cirrhosis and Normal Porcine Liver Using a Cooled-tip Electrode
    Wang, Li-Gang
    Jiang, Wen-Jin
    Fan, Wei-Jun
    Zheng, Yan-Bo
    Song, Xue-Peng
    Liu, Sheng
    Sun, Bo-Lin
    Wang, Tao
    ANTICANCER RESEARCH, 2016, 36 (03) : 1221 - 1226
  • [7] Radio-frequency ablation of colorectal liver metastases in 167 patients
    Gillams, AR
    Lees, WR
    EUROPEAN RADIOLOGY, 2004, 14 (12) : 2261 - 2267
  • [8] Radio-frequency ablation of colorectal liver metastases in 167 patients
    A. R. Gillams
    W. R. Lees
    European Radiology, 2004, 14 : 2261 - 2267
  • [9] Saline-enhanced radio-frequency tissue ablation in the treatment of liver metastases
    Livraghi, T
    Goldberg, SN
    Monti, F
    Bizzini, A
    Lazzaroni, S
    Meloni, F
    Pellicano, S
    Solbiati, L
    Gazelle, GS
    RADIOLOGY, 1997, 202 (01) : 205 - 210
  • [10] Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases
    Goldberg, SN
    Solbiati, L
    Hahn, PF
    Cosman, E
    Conrad, JE
    Fogle, R
    Gazelle, GS