Label-free supersandwich electrogenerated chemiluminescence biosensor for the determination of the HIV gene

被引:0
|
作者
Sanpeng Ruan
Zhejian Li
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Lab of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry & Chemical Engineering
来源
Microchimica Acta | 2014年 / 181卷
关键词
DNA hybridization; Electrogenerated chemiluminescence; Human immunodeficiency virus-1 gene; Supersandwich model;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a highly sensitive electrochemiluminescence (ECL) based method for the determination of the human immunodeficiency virus-1 (HIV-1) gene. A long-range self-assembled double strand DNA (ds-DNA) is used as a carrier, and the ruthenium complex Ru(phen)32+ as an ECL indicator for signal amplification. The thiolated ss-DNA serving as a capture probe is firstly self-assembled on the surface of a gold electrode. After the target HIV-1 gene is completely hybridized with the capture probe, two previously hybridized auxiliary probes are hybridized with the target HIV-1 gene to form long-range supersandwich ds-DNA polymers on the surface of the electrode. Finally, the ECL indicator is intercalated into the supersandwich ds-DNA grooves. This results in a strongly increased ECL in tripropylamine solution because a large fraction of the intercalator is intercalated into supersandwich ds-DNA. The results showed that the increased ECL intensity is directly related to the logarithm of the concentration of the HIV-1 gene in the range from 0.1 pM to 0.1 nM, with a detection limit of 0.022 pM and using only 10 μL of analyte samples. The method can effectively discriminate target HIV-1 gene (a perfectly matched ss-DNA) from a 2-base mismatched ss-DNA. This work demonstrates that the high sensitivity and selectivity of an ECL DNA biosensor can be largely improved by using supersandwich ds-DNA along with ECL indicators.
引用
收藏
页码:1293 / 1300
页数:7
相关论文
共 50 条
  • [1] Label-free supersandwich electrogenerated chemiluminescence biosensor for the determination of the HIV gene
    Ruan, Sanpeng
    Li, Zhejian
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1293 - 1300
  • [2] Cyclometalated Iridium-Complex-Based Label-Free Supersandwich Electrogenerated Chemiluminescence Biosensor for the Detection of Micro-RNA
    Zhao, Ying
    Yang, Xiaolin
    Han, Danjuan
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    CHEMELECTROCHEM, 2017, 4 (07): : 1775 - 1782
  • [3] A label-free supersandwich electrogenerated chemiluminescence method for the detection of DNA methylation and assay of the methyltransferase activity
    Li, Yan
    Luo, Xiaoe
    Yan, Zhao
    Zheng, Jianbin
    Qi, Honglan
    CHEMICAL COMMUNICATIONS, 2013, 49 (37) : 3869 - 3871
  • [4] Label-free and sensitive electrogenerated chemiluminescence aptasensor for the determination of lysozyme
    Li, Yan
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2733 - 2736
  • [5] Electrogenerated chemiluminescence energy transfer for the label-free detection of DNA
    Guo, Zhihui
    Yang, Fan
    Zhang, Lihong
    Zheng, Xingwang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 316 - 321
  • [6] Label-Free Biosensor
    Zhang, Pengfei
    Wang, Rui
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [7] Label-free electrogenerated chemiluminescence biosensor for quantization of CD44 on basis of its heterodimerization with matrix metalloproteinase-14
    Duan, Yuhong
    Xu, Lu
    Song, Wenyu
    Gao, Hui
    Sun, Lina
    Chen, Fangfang
    Ma, Fen
    MICROCHEMICAL JOURNAL, 2022, 182
  • [8] Electrogenerated chemiluminescence energy transfer and its application in label-free sensing long DNA
    Guo, Zhihui
    Kong, Huifang
    Yang, Fan
    Chen, Ting
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 270 - 278
  • [9] Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine
    Li, Yan
    Qi, Honglan
    Peng, Yage
    Yang, Jia
    Zhang, Chengxiao
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) : 2571 - 2575
  • [10] A label-free and sensitive supersandwich electrochemical biosensor for small molecule detection based on target-induced aptamer displacement
    Yang, Xiaohai
    Zhu, Jinqing
    Wang, Qing
    Wang, Kemin
    Yang, Lijuan
    Zhu, Hongzhi
    ANALYTICAL METHODS, 2012, 4 (08) : 2221 - 2223