Exergy efficiency and irreversibility comparison of R22, R134a, R290 and R407C to replace R22 in an air conditioning system

被引:1
作者
Venkataramana Murthy V. Padmanabhan
Senthil Kumar Palanisamy
机构
[1] K. S. Rangasamy College of Technology,Department of Mechanical Engineering
[2] K. S. R. College of Engineering,Department of Mechanical Engineering
来源
Journal of Mechanical Science and Technology | 2013年 / 27卷
关键词
R22; Propane; R407C; Air conditioner; Ir-reversibility; Exergy efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
This work presents an experimental comparison of exergy efficiency (EE), irreversibility at the process 1–2 (evaporator exit to compressor inlet), 2–3 (compressor inlet to condenser inlet), 3–4 (condenser inlet to expansion valve inlet), 4–5 (expansion valve inlet to evaporator inlet) and 5–1 (evaporator), and coefficient of performance (COP) of R22, and its substitutes R134a, R290 and R407C in vapor compression refrigeration system (VCRS) of an air conditioner. In addition, the effects of air temperature in the freezer with reference to environment states on irreversibility and EE have been investigated. At −18°C air temperature in the freezer, 33°C reference environment state and 42% relative humidity refrigerants R22 and its substitutes R134a, R290 and R407C VCRSs the total irreversibilities are 665.7, 753.5, 582.1 and 677 W, and EEs are 22.9, 14.2, 26.5 and 20.6%, respectively. The refrigerant R290 is the best performer among candidate refrigerants but it suffers from flammability. Thus, R407C can considerably be used to replace R22.
引用
收藏
页码:917 / 926
页数:9
相关论文
共 86 条
[21]  
Jung D(2009)Performance characteristics and energy, exergy analysis of solar assisted heat pump system Energ Building 41 154-163
[22]  
Park K-J(2008)Exergetic and economic optimization of a refrigeration evaporator coil with continuous fins Build Environ 43 1961-1972
[23]  
Shim Y-B(2007)Sequence method of determination of partial exergy losses in thermal systems J. Energy Resource Technology 129 266-90
[24]  
Jung D(2001)Exergy analysis and experimental study of heat pump systems Exergy Int. J. 1 85-265
[25]  
Rosen M A(2002)Exergy analysis of multistage cascade low temperature refrigeration systems used in olefin plants Exergy Int. J. 2 259-294
[26]  
Calm J M(2009)Exergetic analysis of carbon dioxide Vapour compression refrigeration cycle using the new fundamental equation of state Int J Refrigeration 32 279-3278
[27]  
Hourahan G C(2003)Transcritical CO2 heat pump systems Exergy analysis including heat transfer and fluid flow effects Energ Convers Manage 44 3267-2067
[28]  
Rosen M(2005)Thermoeconomic optimization of subcooled and superheated vapour compression refrigeration cycle Energ Convers Manage 46 2053-2128
[29]  
Dincer I(2006)Advanced exergetic evaluation of refrigeration machines using different working fluids Energy 31 2108-2258
[30]  
Rosen M(2009)Refrigeration plant exergetic analysis varying the compressor capacity Energy 34 2248-669