A twin-channel difference model for cross-calibration of thermal infrared band

被引:0
作者
JiaGuo Li
XingFa Gu
Tao Yu
XiaoYing Li
HaiLiang Gao
Li Liu
Hui Xu
机构
[1] Chinese Academy of Sciences,State Key Laboratory of Remote Sensing Science, Institute of Remote Sensing Applications
来源
Science China Technological Sciences | 2012年 / 55卷
关键词
remote sensing; cross-calibration; difference model; IRS; MODIS;
D O I
暂无
中图分类号
学科分类号
摘要
Based on the conduction and transformation of the thermal infrared radiative transfer equation of water target, a twin-channel difference model (DM) was proposed to improve the calibration precision by conquering the limitation that the atmospheric condition when image is acquiring cannot be truly obtained in the traditional radiometric simulation calibration method. The analysis of surface, atmosphere and top-of-atmosphere (TOA) radiative energy decomposition demonstrated that the apparent TOA radiance of the uncalibrated channel is the differential combination of two reference channels. The DM avoids impacts from atmospheric temperature and density. The only impact is from water vapor (WV) content. Based on the fitting error analysis of 742 mid-latitude atmospheric profiles (column WV content: 0–5×103 atm cm) selected from TIGR database, the DM is insensitive to WV content. The maximum error is less than 0.2 K when the view zenith angels (VZAs) of reference channels and uncalibrated channel are less than 30°. The error becomes 0.3 K when VZAs range from 30° to 40° and 0.6 K when VZAs are in 40°–50°. Because the uncertainty increases when VZAs are larger than 50°, the best range of VZAs is 30°–50°. The vicarious calibration results at Lake Qinghai field indicated that the calibration precision of the DM cross-calibration by using MODIS bands 31 and 32 as reference channels to calibrate IRS band 08 is similar to that of vicarious calibration. Therefore, the DM is a reliable alternative tool for sensor on-orbit calibration and validation with high precision and frequency.
引用
收藏
页码:2048 / 2056
页数:8
相关论文
共 43 条
  • [1] Merchant C. J.(2003)A cross-calibration of GMS-5 thermal channels against ATSR-2 Remote Sensing Env 84 268-28
  • [2] Simpson J. J.(2009)Intercalibration of SVISSR/FY-2C infrared channels against MODIS/Terra and AIRS/Aqua channels IEEE Trans Geosci Remote Sensing 47 1548-1558
  • [3] Harris A. R.(2001)Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data sets Remote Sensing Env 78 39-54
  • [4] Jiang G. M.(2002)Using Moderate Resolution Imaging Spectrometer (MODIS) to calibrate advanced very high resolution radiometer reflectance channels J Geophys Res 107 4702-562
  • [5] Yan H.(1987)Calibration of METEOSAT infrared radiometer using split-window channels of NOAA AVHRR J Atmos Oceanic Tech 4 553-5281
  • [6] Ma L. L.(2004)A new method for cross-calibration of two satellite sensors Int J Remote Sensing 25 5267-220
  • [7] Teillet P. M.(2006)Calibration of NOAA16 AVHRR over a dersert site using MODIS data Remote Sensing Env 105 214-68
  • [8] Barker J. L.(2010)Tracking long-term stability of Aqua MODIS and AIRS at different scan angles Proceedings of SPIE 7807 780718-28
  • [9] Markham B. L.(2004)Intercalibration of the infrared window and water vapor channels on operational geostationary environmental satellites using a single polar-orbiting satellite J Atmos Ocean Technol 21 61-117
  • [10] Heidinger A. K.(2007)Intercalibration geostationary imagers via polar orbiting high spectral resolution data SPIE Int Soc Opt Eng Atmos Environ Remote Sens Data Process. Utilization III: Readiness GEOSS, San Diego, CA 6684 27-12