Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation

被引:0
作者
Hiroto Tamaru
Kenichi Fujii
Tsuyoshi Nakata
Masashi Fukunaga
Takahiro Imanaka
Kenji Kawai
Kojiro Miki
Tetsuo Horimatsu
Machiko Nishimura
Ten Saita
Akinori Sumiyoshi
Masahiko Shibuya
Yoshiro Naito
Tohru Masuyama
Masaharu Ishihara
机构
[1] Hyogo College of Medicine,Division of Cardiovascular Medicine and Coronary Heart Disease
来源
Cardiovascular Intervention and Therapeutics | 2019年 / 34卷
关键词
Drug-eluting stent; Endothelial function; Optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated the impact of optical coherence tomography (OCT)-derived low-backscattered tissue on mid-term coronary endothelial function after drug-eluting stent (DES) implantation. Although OCT enables detailed in vivo evaluation of neointimal tissue characterization after DES implantation, its association with physiological vascular healing response is unclear. Thirty-three stable angina pectoris patients underwent OCT examination and endothelial function testing with intracoronary infusion of incremental doses of acetylcholine 8-month after DES implantation in a single lesion of the left anterior descending artery. Neointimal tissue was classified into two patterns based on the predominant OCT light backscatter: high backscatter and low backscatter. Although the presence of uncovered or malapposed stent strut was not associated with the degree of vasoconstriction, the degree of vasoconstriction was significantly greater in the DES with low-backscattered neointima than in the DES without low-backscattered neointima (− 32.1 ± 25.7 vs. − 4.1 ± 20.1%, p = 0.003). Moreover, there was an inverse linear relationship between low backscatter tissue index and degree of vasoconstriction after acetylcholine infusion (r = 0.50 and p = 0.003). The endothelium-dependent vasomotor response after 8-month of DES was impaired in patients with low neointimal tissue backscatter on OCT imaging. OCT assessment of low-backscattered tissue may be used as surrogate markers for impairment of endothelial function after DES.
引用
收藏
页码:164 / 170
页数:6
相关论文
共 153 条
[21]  
Hosogi S(2010)Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation JACC Cardiovasc Imaging 3 76-84
[22]  
Miyake K(2006)Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation Eur Heart J 27 166-170
[23]  
Amano H(2008)Six-month comparison of coronary endothelial dysfunction associated with sirolimus-eluting stent versus Paclitaxel-eluting stent JACC Cardiovasc Interv 1 65-71
[24]  
Nakamura M(2016)Morphological, functional, and biological vascular healing response 6 months after drug-eluting stent implantation: a randomized comparison of three drug-eluting stents Catheter Cardiovasc Interv 88 350-357
[25]  
Yonetsu T(2010)Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: optical coherence tomographic analysis JACC Cardiovasc Interv 3 1074-1079
[26]  
Kim JS(2014)Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model EuroIntervention 10 717-723
[27]  
Kato K(2014)Long-term vascular responses to Resolute J Interv Cardiol 27 381-390
[28]  
Kim SJ(2008) and Xience V Circ Cardiovasc Interv 1 193-200
[29]  
Xing L(2015) polymer-based drug-eluting stents in a rabbit model of atherosclerosis Cardiovasc Revasc Med 16 351-357
[30]  
Yeh RW(undefined)Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses undefined undefined undefined-undefined