Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography

被引:0
|
作者
Sofie Bech Andersen
Iman Taghavi
Hans Martin Kjer
Stinne Byrholdt Søgaard
Carsten Gundlach
Vedrana Andersen Dahl
Michael Bachmann Nielsen
Anders Bjorholm Dahl
Jørgen Arendt Jensen
Charlotte Mehlin Sørensen
机构
[1] University of Copenhagen,Department of Biomedical Sciences
[2] Rigshospitalet,Department of Radiology
[3] Technical University of Denmark,Center for Fast Ultrasound Imaging, Department of Health Technology
[4] Technical University of Denmark,Department of Applied Mathematics and Computer Science
[5] Technical University of Denmark,Department of Physics
[6] University of Copenhagen,Department of Clinical Medicine
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Super-resolution ultrasound imaging (SRUS) enables in vivo microvascular imaging of deeper-lying tissues and organs, such as the kidneys or liver. The technique allows new insights into microvascular anatomy and physiology and the development of disease-related microvascular abnormalities. However, the microvascular anatomy is intricate and challenging to depict with the currently available imaging techniques, and validation of the microvascular structures of deeper-lying organs obtained with SRUS remains difficult. Our study aimed to directly compare the vascular anatomy in two in vivo 2D SRUS images of a Sprague–Dawley rat kidney with ex vivo μCT of the same kidney. Co-registering the SRUS images to the μCT volume revealed visually very similar vascular features of vessels ranging from ~ 100 to 1300 μm in diameter and illustrated a high level of vessel branching complexity captured in the 2D SRUS images. Additionally, it was shown that it is difficult to use μCT data of a whole rat kidney specimen to validate the super-resolution capability of our ultrasound scans, i.e., validating the actual microvasculature of the rat kidney. Lastly, by comparing the two imaging modalities, fundamental challenges for 2D SRUS were demonstrated, including the complexity of projecting a 3D vessel network into 2D. These challenges should be considered when interpreting clinical or preclinical SRUS data in future studies.
引用
收藏
相关论文
共 50 条
  • [21] Face image super-resolution using 2D CCA
    An, Le
    Bhanu, Bir
    SIGNAL PROCESSING, 2014, 103 : 184 - 194
  • [22] Face image super-resolution using 2D CCA
    An, Le
    Bhanu, Bir
    Signal Processing, 2014, 103 : 184 - 194
  • [23] Face image super-resolution using 2D CCA
    An, L. (lan004@ucr.edu), 1600, Elsevier B.V., Netherlands (103):
  • [24] Ex vivo micro-computed tomography analysis of bleomycin-induced lung fibrosis for preclinical drug evaluation
    Scotton, Chris J.
    Hayes, Brian
    Alexander, Robert
    Datta, Arnab
    Forty, Ellen J.
    Mercer, Paul F.
    Blanchard, Andy
    Chambers, Rachel C.
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42 (06) : 1633 - 1645
  • [25] Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study
    Cinar, Firdevs
    Ustun, Yakup
    EUROPEAN ENDODONTIC JOURNAL, 2020, 5 (03): : 226 - 230
  • [26] Underestimation of Flow Velocity in 2-D Super-Resolution Ultrasound Imaging
    Naji, Mostafa Amin
    Taghavi, Iman
    Thomsen, Erik Vilain
    Larsen, Niels Bent
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (12) : 1844 - 1854
  • [27] Improving anisotropy resolution of computed tomography and annotation using 3D super-resolution network
    Ge, Rongjun
    Shi, Fanqi
    Chen, Yang
    Tang, Shujun
    Zhang, Hailong
    Lou, Xiaojian
    Zhao, Wei
    Coatrieux, Gouenou
    Gao, Dazhi
    Li, Shuo
    Mai, Xiaoli
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 82
  • [28] An ex-vivo setup for characterization of atherosclerotic plaque using shear wave elastography and micro-computed tomography
    Larsson, David
    Roy, Joy
    Gasser, T. Christian
    Urban, Matthew W.
    Colarieti-Tosti, Massimiliano
    Larsson, Matilda
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [29] Application of ex vivo micro-computed tomography for assessment of in vivo fluorescence and plain radiographic imaging for monitoring bone metastases and osteolytic lesions
    Sanjay Tiwari
    Christian Schem
    Ann-Christin Lorenzen
    Ole Kayser
    Claas Wiese
    Christian Graeff
    Jaime Peña
    Robert P. Marshall
    Martin Heller
    Holger Kalthoff
    Walter Jonat
    Claus-C Glüer
    Journal of Bone and Mineral Metabolism, 2012, 30 : 373 - 380
  • [30] Application of ex vivo micro-computed tomography for assessment of in vivo fluorescence and plain radiographic imaging for monitoring bone metastases and osteolytic lesions
    Tiwari, Sanjay
    Schem, Christian
    Lorenzen, Ann-Christin
    Kayser, Ole
    Wiese, Claas
    Graeff, Christian
    Pena, Jaime
    Marshall, Robert P.
    Heller, Martin
    Kalthoff, Holger
    Jonat, Walter
    Glueer, Claus-C
    JOURNAL OF BONE AND MINERAL METABOLISM, 2012, 30 (03) : 373 - 380