Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood

被引:0
|
作者
Mathias Reisbeck
Michael Johannes Helou
Lukas Richter
Barbara Kappes
Oliver Friedrich
Oliver Hayden
机构
[1] In-Vitro DX & Bioscience,Department of Strategy and Innovation
[2] Siemens Healthcare GmbH,Department of Chemical and Biological Engineering
[3] Institute of Medical Biotechnology,undefined
[4] Friedrich-Alexander-University Erlangen-Nuremberg (FAU),undefined
来源
Scientific Reports | / 6卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Over the past 50 years, flow cytometry has had a profound impact on preclinical and clinical applications requiring single cell function information for counting, sub-typing and quantification of epitope expression. At the same time, the workflow complexity and high costs of such optical systems still limit flow cytometry applications to specialized laboratories. Here, we present a quantitative magnetic flow cytometer that incorporates in situ magnetophoretic cell focusing for highly accurate and reproducible rolling of the cellular targets over giant magnetoresistance sensing elements. Time-of-flight analysis is used to unveil quantitative single cell information contained in its magnetic fingerprint. Furthermore, we used erythrocytes as a biological model to validate our methodology with respect to precise analysis of the hydrodynamic cell diameter, quantification of binding capacity of immunomagnetic labels, and discrimination of cell morphology. The extracted time-of-flight information should enable point-of-care quantitative flow cytometry in whole blood for clinical applications, such as immunology and primary hemostasis.
引用
收藏
相关论文
共 50 条
  • [21] Dendritic cells subsets in whole blood revealed by a single-platform flow cytometry assay.
    Vuckovic, S
    Gardiner, D
    Khalil, D
    Field, K
    Pinzon-Charry, A
    Rodwell, R
    Chapman, GV
    Hart, DNJ
    BLOOD, 2002, 100 (11) : 41B - 41B
  • [22] A new simple whole blood flow cytometry-based method for simultaneous identification of activated cells and quantitative evaluation of cytokines released during activation
    Rodríguez-Caballero, A
    García-Montero, AC
    Bueno, C
    Almeida, J
    Varro, R
    Chen, R
    Pandiella, A
    Orfao, A
    LABORATORY INVESTIGATION, 2004, 84 (10) : 1387 - 1398
  • [23] FLOW CYTOMETRY FOR WHITE BLOOD-CELL COUNTS IN WHOLE-BLOOD AND BLOOD COMPONENTS
    RADTKE, H
    LINDENAU, S
    HOLBACH, B
    NEUMANN, S
    KIESEWETTER, H
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 : 112 - 114
  • [24] Counting absolute number of lymphocytes in quail whole blood by flow cytometry
    Uchiyama, R
    Moritomo, T
    Kai, O
    Uwatoko, K
    Inoue, Y
    Nakanishi, T
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2005, 67 (04): : 441 - 444
  • [25] Platelet calcium flux measurement by flow cytometry in diluted whole blood
    Wilbourn, B.
    Riddell, A.
    Foxton, E.
    Gomez, K.
    Chowdary, P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 : 114 - 115
  • [26] Fiber-optic multiphoton flow cytometry in whole blood and in vivo
    Chang, Yu-Chung
    Ye, Jing Yong
    Thomas, Thommey P.
    Cao, Zhengyi
    Kotlyar, Alina
    Tkaczyk, Eric R.
    Baker, James R., Jr.
    Norris, Theodore B.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)
  • [27] Investigation of platelet-neutrophil interactions in whole blood by flow cytometry
    Peters, MJ
    Heyderman, RS
    Hatch, DJ
    Klein, NJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 209 (02) : 125 - 135
  • [28] Reticulocytes and reticulated platelets: Simultaneous measurement in whole blood by flow cytometry
    Rapi, S
    Ermini, A
    Bartolini, L
    Caldini, A
    Del Genovese, A
    Miele, AR
    Buggiani, A
    Fanelli, A
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (04) : 211 - 214
  • [29] Quantitation of platelet aggregation and microaggregate formation in whole blood by flow cytometry
    Fox, SC
    Sasae, R
    Janson, S
    May, JA
    Heptinstall, S
    PLATELETS, 2004, 15 (02) : 85 - 93
  • [30] The effects of aprotinin on platelets in vitro using whole blood flow cytometry
    Kozek-Langenecker, SA
    Mohammad, SF
    Masaki, T
    Green, W
    Kamerath, C
    Cheung, AK
    ANESTHESIA AND ANALGESIA, 2000, 90 (01): : 12 - 16