Organic solvent effects in reversed-phase liquid chromatography in relation to column testing

被引:0
作者
K. Le Mapihan
J. Vial
A. Jardy
机构
[1] UMR 7121,Laboratoire Environnement et Chimie Analytique
[2] Ecole Supérieure de Physique et de Chimie Industrielles de la Ville de Paris 10,undefined
来源
Chromatographia | 2003年 / 57卷
关键词
Column liquid chromatography; Column testing; Solvent effect; Neutral and basic compounds;
D O I
暂无
中图分类号
学科分类号
摘要
The solvent effects during RPLC column characterization was evalauted. A test derived from that of Tanaka was performed using both methanol and acetonitrile as organic modifier. Neutral and basic solutes were used to assess the solvent impact on the chromatographic properties of stationary phases. A cross-interaction was often observed between the column and the solvent which means that both the choice of column and solvent must be taken into account during characetrization.
引用
收藏
页码:S163 / S170
相关论文
共 50 条
  • [1] Organic solvent effects in reversed-phase liquid chromatography in relation to column testing
    Le Mapihan, K
    Vial, J
    Jardy, A
    CHROMATOGRAPHIA, 2003, 57 (Suppl 1) : S163 - S170
  • [2] Reversed-phase liquid chromatography column testing: robustness study of the test
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) : 149 - 158
  • [3] Reversed-phase liquid chromatography testing - Role of organic solvent through an extended set of columns
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) : 16 - 23
  • [4] Testing of "special base" columns in reversed-phase liquid chromatography - A rational approach considering solvent effects
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) : 135 - 147
  • [5] TOLUENE POLYMER AS A NEW STATIONARY PHASE IN REVERSED-PHASE COLUMN LIQUID-CHROMATOGRAPHY
    NASUTO, R
    KWIETNIEWSKI, L
    CHROMATOGRAPHIA, 1990, 29 (11-12) : 597 - 602
  • [6] Reversed-phase liquid chromatography column testing and classification: Physicochemical interpretation based on a wide set of stationary phases
    Le Mapihan, K.
    Vial, J.
    Jardy, A.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (02) : 183 - 196
  • [7] OPTIMIZING SEPARATIONS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY BY VARYING PH AND SOLVENT COMPOSITION
    SCHOENMAKERS, PJ
    MACKIE, N
    MARQUES, RML
    CHROMATOGRAPHIA, 1993, 35 (1-2) : 18 - 32
  • [8] EFFECT OF THE ORGANIC MODIFIER ON THE RETENTION OF RETINOIDS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    SALO, M
    VUORELA, H
    HALMEKOSKI, J
    CHROMATOGRAPHIA, 1993, 36 : 147 - 151
  • [9] The temperature convergence of biopolymers in reversed-phase liquid chromatography
    Quan Bai
    Xindu Geng
    Chromatographia, 2001, 54 : 335 - 338
  • [10] The temperature convergence of biopolymers in reversed-phase liquid chromatography
    Bai, Q
    Geng, XD
    CHROMATOGRAPHIA, 2001, 54 (5-6) : 335 - 338