A new sorbent based on MWCNTs modification for separation/preconcentration of trace amounts of Cd(II), Cr(III), Cu(II), Ni(II), and Pb(II) and their determination by flame atomic absorption spectrometry

被引:1
|
作者
Karimi M.A. [1 ,2 ]
Mohammadi S.Z. [1 ]
Hatefi-Mehrjardi A. [2 ]
Mohadesi A. [1 ]
Yarahmadi J. [2 ]
机构
[1] Department of Chemistry, Payame Noor University, P.O. Box 19395-4697, Tehran
[2] Department of Chemistry & Nanoscience and Nanotechnology Research Laboratory (NNRL), Payame Noor University, P.O. Box 78185-347, Sirjan
基金
美国国家科学基金会;
关键词
Ethylenediamine-N; N-diacetic acid; Flame atomic absorption spectrometry; Heavy metals; Multiwalled carbon nanotubes; Solid phase extraction;
D O I
10.1186/s40543-015-0065-2
中图分类号
学科分类号
摘要
Background: A new solid phase extraction (SPE) method has been developed for the separation/preconcentration and determination of lead, cadmium, chromium, nickel, and copper ions using a new sorbent. Methods: The method is based on the application of multiwalled carbon nanotubes modified with ethylenediamine-N,N-diacetic acid (MWCNTs-EDDA) as a selective sorbent in SPE for the separation and preconcentration of Pb(II), Ni(II), Cd(II), Cu(II), and Cr(III). The determination of these heavy metals was followed by flame atomic absorption spectrometry (FAAS). Results: All quantitative determinations were performed by FAAS, and surface modification of synthesized adsorbents has been confirmed on the basis of characterization with Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The parameters such as pH, amount of adsorbent, shaking time, eluent type and its concentration, and matrix effect have been investigated and optimized. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 51.7, 67.6, 49.9, 57.8, and 62.3 mg g-1 for Cd(II), Cr(III), Cu(II), Ni(II), and Pb(II), respectively. Conclusions: In the presented study, MWCNTs were functionalized by EDDA and it was applied as an adsorbent for the separation and preconcentration of trace level of Pb, Ni, Cd, Cu, and Cr ions. This method is effective, selective, rapid, and simple for the determination of trace amounts of Pb, Ni, Cd, Cu, and Cr ions and can be successfully applied to analyze the trace amounts of mentioned ions in wastewater and herbal samples without evident interference from the complex matrix. Furthermore, the sorption has high capacity, and the precision and accuracy of the method are also satisfactory. © 2015, Karimi et al.
引用
收藏
相关论文
共 50 条
  • [31] A surface ion-imprinted mesoporous sorbent for separation and determination of Pb(II) ion by flame atomic absorption spectrometry
    Liu, Yan
    Liu, Zhanchao
    Wang, Yun
    Dai, Jiangdong
    Gao, Jie
    Xie, Jimin
    Yan, Yongsheng
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 309 - 317
  • [32] Determination of Trace Amounts of Cd(II), Cu(II), and Ni(II) in Food Samples Using a Novel Functionalized Magnetic Nanosorbent
    Bagheri, Hasan
    Asgharinezhad, Ali Akbar
    Ebrahimzadeh, Homeira
    FOOD ANALYTICAL METHODS, 2016, 9 (04) : 876 - 888
  • [33] Coal Cinder Separation/Preconcentration of Trace Cu, Pb, and Cd in Environmental Water Samples and Determination by Flame Atomic Absorption Spectrometry
    Wei, Xiao-Shu
    Yu, Ai-Min
    Han, Mu-Xian
    Zhang, Jing
    Zhang, Hai-Li
    Wu, Yi-Wei
    ATOMIC SPECTROSCOPY, 2012, 33 (02) : 67 - 72
  • [34] Simultaneous separation and preconcentration of ultra-trace of Cu(II), Pb(II) and Zn(II) in water samples by air-assisted liquid-liquid microextraction prior to determination by graphite furnace atomic absorption spectrometry
    Sorouraddin, Saeed Mohammad
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2016, 13 (12) : 2219 - 2227
  • [35] Cysteine modified silica submicrospheres as a new sorbent for preconcentration of Cd (II) and Pb (II)
    Dakova, I.
    Vasileva, P.
    Karadjova, I.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2011, 43 (02): : 210 - 216
  • [36] Simultaneous separation and preconcentration of Cr(III), Cu(II), Cd(II) and Pb(II) from environmental samples prior to inductively coupled plasma optical emission spectrometric determination
    Zhang, Li
    Li, Zhenhua
    Du, Xianghui
    Li, Ruijun
    Chang, Xijun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 86 : 443 - 448
  • [37] A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry
    Dasbasi, Teslima
    Sacmaci, Serife
    Ulgen, Ahmet
    Kartal, Senol
    FOOD CHEMISTRY, 2015, 174 : 591 - 596
  • [38] Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination
    Riazati, D.
    Aibaghi-Esfahani, B.
    Fayazi, M.
    Ghanei-Motlagh, M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (01): : 1 - 12
  • [39] Flame atomic absorption spectrometric determination of Cd(II), Ni(II), Co(II) and Cu(II) in tea and water samples after simultaneous preconentration of dithizone loaded on naphthalene
    N. Pourrez
    M. R. Fathi
    Z. Ardan
    Journal of the Iranian Chemical Society, 2010, 7 : 965 - 971
  • [40] Graphene oxide modified expanded perlite as a new sorbent for Cu(II) and Pb(II) prior to determination by high-resolution continuum source flame atomic absorption spectrometry
    Canlidinc, R. Saygili
    Kalfa, O. M.
    Ustundag, Z.
    Erdogan, Y.
    SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (13) : 2069 - 2078