Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: Comparison with a computed radiographic system

被引:16
|
作者
Tanaka N. [1 ]
Yano Y. [1 ]
Yabuuchi H. [2 ]
Akasaka T. [2 ]
Sasaki M. [2 ]
Ohki M. [2 ]
Morishita J. [2 ]
机构
[1] Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Higashi-ku, Fukuoka 812-8582
[2] Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Higashi-ku, Fukuoka 812-8582
关键词
Chest radiography; Image quality; Indirect flat-panel detector (FPD); Irradiation side sampling (ISS); Patient skin dose;
D O I
10.1007/s12194-012-0184-z
中图分类号
学科分类号
摘要
The image quality and potential usefulness for patient skin-dose reduction of a newly developed flat-panel detector (FPD) system employing irradiation side sampling (ISS) were investigated and compared to a conventional computed radiography (CR) system. We used the X-ray beam quality of RQA 9 as noted in the standard evaluation method by the International Electrotechnical Commission 62220-1 to evaluate the image quality of the detector for chest radiography. The presampled modulation transfer function (MTF) of the ISS-FPD system was slightly higher than that of the CR system in the horizontal direction at more than 2.2 cycles/mm. However, the presampled MTF of the ISS-FPD system was slightly lower than that of the CR system in the vertical direction. The Wiener spectrum of the ISS-FPD system showed a 50-65 % lesser noise level than that of the CR system under the same exposure condition. The detective quantum efficiency of the ISS-FPD system was at least twice as great as that of the CR system. We conclude that the ISS-FPD system has the potential to reduce the patient skin dose compared to a conventional CR system for chest radiography. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:162 / 169
页数:7
相关论文
共 31 条
  • [1] Detectability of simulated interstitial pneumonia on chest radiographs: comparison between irradiation side sampling indirect flat-panel detector and computed radiography
    Yano, Y.
    Yabuuchi, H.
    Kairada, A.
    Tanaka, N.
    Morishita, J.
    Akasaka, T.
    Matsuo, Y.
    Kamitani, T.
    Yamasaki, Y.
    Nagao, M.
    Sasaki, M.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1040):
  • [2] Detectability of simulated pulmonary nodules on chest radiographs: Comparison between irradiation side sampling indirect flat-panel detector and computed radiography
    Yano, Yuki
    Yabuuchi, Hidetake
    Tanaka, Nobukazu
    Morishita, Junji
    Akasaka, Tsutomu
    Matsuo, Yoshio
    Sunami, Shunya
    Kamitani, Takeshi
    Jinnouchi, Mikako
    Yamasaki, Yuzo
    Nagao, Michinobu
    Sasaki, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : 2050 - 2054
  • [3] Potential for Dose Reduction in An Indirect Flat Panel Detector System Employing Irradiation Side Sampling
    Tanaka, N.
    Akasaka, T.
    Yabuuchi, H.
    Ohki, M.
    Morishita, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3439 - +
  • [4] Clinical comparison of imaging performance of a digital radiography system with a new flat-panel detector vs computed radiography
    Mildenberger, P
    Vogel, N
    Herber, SS
    Kaemmerer, M
    Thelen, M
    RADIOLOGY, 2000, 217 : 518 - 518
  • [5] Physical properties of a new flat panel detector with irradiated side sampling (ISS) technology
    Fiebich, Martin
    Burg, Jan M.
    Piel, Christina
    Rodenheber, Laura
    Penchev, Petar
    Krombach, Gabriele A.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [6] Flat-Panel Detector Computed Tomography Imaging Observer Performance in Detecting Pulmonary Nodules in Comparison With Conventional Chest Radiography and Multidetector Computed Tomography
    Otani, Hideji
    Nitta, Norihisa
    Ikeda, Mitsuru
    Nagatani, Yukihiro
    Tanaka, Toyohiko
    Kitahara, Hitoshi
    Murakami, Yoko
    Takahashi, Masashi
    Murata, Kiyoshi
    JOURNAL OF THORACIC IMAGING, 2012, 27 (01) : 51 - 57
  • [7] Automated analysis for the respiratory kinetics with the screening dynamic chest radiography using a flat-panel detector system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Inoue, H
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 179 - 186
  • [8] Quantitative analysis of respiratory kinetics in chest screening radiography by dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    RADIOLOGY, 2002, 225 : 187 - 188
  • [9] Comparison of the image quality of a storage phospor system and a flat-panel detector in feline thoracic radiography
    Ludewig, E.
    Werrmann, A.
    Gosch, D.
    Oechtering, G.
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2010, 38 (06): : 355 - 366
  • [10] Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: Comparison with storage phosphor radiography at different exposures by using a chest phantom
    Rapp-Bernhardt, U
    Bernhardt, TM
    Lenzen, H
    Esseling, R
    Roehl, FW
    Schiborr, M
    Theobold-Hormann, I
    Heindel, W
    RADIOLOGY, 2005, 237 (02) : 485 - 491