Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions

被引:0
|
作者
Eva-Eleni Achilleos
Christos Rahiotis
Afrodite Kakaboura
George Vougiouklakis
机构
[1] University of Athens (NKUA),
[2] University of Athens (NKUA),undefined
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Caries detection methods; Fluorescence; DIAGNOdent pen; ICDAS; Caries detection;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this in vitro study was to evaluate the performance of various contemporary detection tools at incipient occlusal caries. Thirty eight freshly extracted posterior teeth with non-cavitated occlusal caries were subjected to clinical examination and coding according to ICDAS criteria (n = 38). Standardized fluorescence images were taken with VistaProof (Dürr Dental, Bietigheim-Bissingen, Germany). Furthermore, the teeth were calculated with a laser fluorescence pen device (DIAGNOdent pen, Kavo, Biberach, Germany). In all detection methods, assessment of caries was performed twice (with 1-week interval) by two calibrated examiners. Finally, the caries lesions were validated in tooth sections by histological examination. The intra-examiner and inter-examiner kappa coefficient, sensitivity, and specificity were determined for all detection methods at enamel lesions (D1 threshold). Degrees of agreement of each method with the histological status were calculated using receiver operating characteristic statistics and the area under curve (Az values). The kappa intra-examiner/inter-examiner coefficient values (mean ± SD) were 0.74 ± 0.04/0.73 ± 0.07, 0.87 ± 0.04/0.82 ± 0.07, and 0.91 ± 0.06/0.83 ± 0.08 for clinical examination, DIAGNOdent pen, and VistaProof, respectively. The sensitivity for ICDAS was 0.80–0.86, for DIAGNOdent pen was 0.66–0.75, and for the VistaProof device was 0.97. The specificity for all the detection methods were 0.5 (0.02–0.99). The accuracy value for ICDAS was 0.76–0.81, for DIAGNOdent pen 0.66–0.71, and for the VistaProof device 0.92–0.95. The Az values (mean ± SD) were 0.431 ± 0.187, 0.583 ± 0.215, and 0.486 ± 0.207 for ICDAS, DIAGNOdent pen, and VistaProof examination, respectively. No significant differences in Az values were noted among the methods. All detection methods were presented with high inter-examiner and intra-examiner agreement. The new VistaProof device showed the best sensitivity, while DIAGNOdent pen demonstrated the worst one. Specificities were the same for all detection methods. Moreover, they presented the same performance in detection of incipient occlusal caries.
引用
收藏
页码:193 / 201
页数:8
相关论文
共 50 条
  • [41] New methodology to assess activity status of occlusal caries in primary teeth using laser fluorescence device
    Braga, Mariana Minatel
    de Benedetto, Monique Saveriano
    Pettorossi Imparato, Jose Carlos
    Mendes, Fausto Medeiros
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)
  • [42] Evaluation of Sensitivity of Fluorescence-Based Asbestos Detection by Correlative Microscopy
    Takenori Ishida
    Maxym Alexandrov
    Tomoki Nishimura
    Kenji Minakawa
    Ryuichi Hirota
    Kiyoshi Sekiguchi
    Norihiko Kohyama
    Akio Kuroda
    Journal of Fluorescence, 2012, 22 : 357 - 363
  • [43] Evaluation of Sensitivity of Fluorescence-Based Asbestos Detection by Correlative Microscopy
    Ishida, Takenori
    Alexandrov, Maxym
    Nishimura, Tomoki
    Minakawa, Kenji
    Hirota, Ryuichi
    Sekiguchi, Kiyoshi
    Kohyama, Norihiko
    Kuroda, Akio
    JOURNAL OF FLUORESCENCE, 2012, 22 (01) : 357 - 363
  • [44] Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: An in vitro study
    Deery, C.
    Iloya, J.
    Nugent, Z. J.
    Srinivasan, V.
    CARIES RESEARCH, 2006, 40 (03) : 186 - 193
  • [45] Effectiveness of Fluorescence-based Methods in Monitoring Progression of Noncavitated Caries-like Lesions on Smooth Surfaces
    Diniz, M. B.
    Campos, P. H.
    Sanabe, M. E.
    Duarte, D. A.
    Santos, M. T. B. R.
    Guare, R. O.
    Duque, C.
    Lussi, A.
    Rodrigues, J. A.
    OPERATIVE DENTISTRY, 2015, 40 (06) : E230 - E241
  • [46] Fluorescence-Based Methods for Detecting Caries Lesions: Systematic Review, Meta-Analysis and Sources of Heterogeneity
    Gimenez, Thais
    Braga, Mariana Minatel
    Raggio, Daniela Procida
    Deery, Chris
    Ricketts, David N.
    Mendes, Fausto Medeiros
    PLOS ONE, 2013, 8 (04):
  • [47] Laser fluorescence system for detection of occlusal caries in third molars.
    Baseren, NM
    Gökalp, S
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 475 - 475
  • [48] Detection of occlusal caries under sealants by use of a laser fluorescence system
    Takamori, K
    Hokari, N
    Okumura, Y
    Watanabe, S
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (05): : 267 - 271
  • [49] Comparison of two laser fluorescence devices for the detection of occlusal caries in vivo
    Krause, F.
    Jepsen, S.
    Braun, A.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2007, 115 (04) : 252 - 256
  • [50] Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro
    Lussi, A
    Imwinkelried, S
    Pitts, NB
    Longbottom, C
    Reich, E
    CARIES RESEARCH, 1999, 33 (04) : 261 - 266