Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions

被引:0
|
作者
Eva-Eleni Achilleos
Christos Rahiotis
Afrodite Kakaboura
George Vougiouklakis
机构
[1] University of Athens (NKUA),
[2] University of Athens (NKUA),undefined
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Caries detection methods; Fluorescence; DIAGNOdent pen; ICDAS; Caries detection;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this in vitro study was to evaluate the performance of various contemporary detection tools at incipient occlusal caries. Thirty eight freshly extracted posterior teeth with non-cavitated occlusal caries were subjected to clinical examination and coding according to ICDAS criteria (n = 38). Standardized fluorescence images were taken with VistaProof (Dürr Dental, Bietigheim-Bissingen, Germany). Furthermore, the teeth were calculated with a laser fluorescence pen device (DIAGNOdent pen, Kavo, Biberach, Germany). In all detection methods, assessment of caries was performed twice (with 1-week interval) by two calibrated examiners. Finally, the caries lesions were validated in tooth sections by histological examination. The intra-examiner and inter-examiner kappa coefficient, sensitivity, and specificity were determined for all detection methods at enamel lesions (D1 threshold). Degrees of agreement of each method with the histological status were calculated using receiver operating characteristic statistics and the area under curve (Az values). The kappa intra-examiner/inter-examiner coefficient values (mean ± SD) were 0.74 ± 0.04/0.73 ± 0.07, 0.87 ± 0.04/0.82 ± 0.07, and 0.91 ± 0.06/0.83 ± 0.08 for clinical examination, DIAGNOdent pen, and VistaProof, respectively. The sensitivity for ICDAS was 0.80–0.86, for DIAGNOdent pen was 0.66–0.75, and for the VistaProof device was 0.97. The specificity for all the detection methods were 0.5 (0.02–0.99). The accuracy value for ICDAS was 0.76–0.81, for DIAGNOdent pen 0.66–0.71, and for the VistaProof device 0.92–0.95. The Az values (mean ± SD) were 0.431 ± 0.187, 0.583 ± 0.215, and 0.486 ± 0.207 for ICDAS, DIAGNOdent pen, and VistaProof examination, respectively. No significant differences in Az values were noted among the methods. All detection methods were presented with high inter-examiner and intra-examiner agreement. The new VistaProof device showed the best sensitivity, while DIAGNOdent pen demonstrated the worst one. Specificities were the same for all detection methods. Moreover, they presented the same performance in detection of incipient occlusal caries.
引用
收藏
页码:193 / 201
页数:8
相关论文
共 50 条
  • [21] Association between quantitative measures obtained using fluorescence-based methods and activity status of occlusal caries lesions in primary molars
    Novaes, Tatiane Fernandes
    Reyes, Alessandra
    Matos, Ronilza
    Antunes-Pontes, Laura Regina
    de Samuel Marques, Renata Pereira
    Braga, Mariana Minatel
    Diniz, Michele Baffi
    Mendes, Fausto Medeiros
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2017, 27 (03) : 154 - 162
  • [22] Histological validation of a laser fluorescence device for occlusal caries detection in primary molars.
    Apostolopoulou D.
    Lagouvardos P.
    Kavvadia K.
    Papagiannoulis L.
    European Archives of Paediatric Dentistry, 2009, 10 (Suppl 1) : 11 - 15
  • [23] Clinical study of the use of the laser fluorescence device DIAGNOdent for detection of occlusal caries in children
    Anttonen, V
    Seppä, L
    Hausen, H
    CARIES RESEARCH, 2003, 37 (01) : 17 - 23
  • [24] Clinical performance of a diode laser fluorescence device for the detection of occlusal caries in primary teeth
    Kavvadia, Katerina
    Lagouvardos, Panagiotis
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2008, 18 (03) : 197 - 204
  • [25] Comparison between a laser fluorescence device and visual examination in the detection of occlusal caries in children
    Kouchaji, Chaza
    SAUDI DENTAL JOURNAL, 2012, 24 (3-4) : 169 - 174
  • [26] Diagnostic Drama. Use of ICDAS II and Fluorescence-Based Intraoral Camera in Early Occlusal Caries Detection: A Clinical Study
    Mazur, Marta
    Jedlinski, Maciej
    Ndokaj, Artnora
    Corridore, Denise
    Maruotti, Antonello
    Ottolenghi, Livia
    Guerra, Fabrizio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (08)
  • [27] In vitro validity of a laser-based device for occlusal caries detection
    Longbottom, C
    Ferrier, S
    Pitts, NB
    Deery, C
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1044 - 1044
  • [28] Detection of approximal caries with a new laser fluorescence device
    Lussi, A
    Hack, A
    Hug, I
    Heckenberger, H
    Megert, B
    Stich, H
    CARIES RESEARCH, 2006, 40 (02) : 97 - 103
  • [29] Optical sensitivity of laser fluorescence of incipient caries detection
    Kim, HS
    Lee, CS
    Lee, SH
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1144 - 1144
  • [30] Performance of a fluorescence camera for detection of occlusal caries in vitro
    Jablonski-Momeni, Anahita
    Schipper, Helge Marten
    Rosen, Simon Martin
    Heinzel-Gutenbrunner, Monika
    Roggendorf, Matthias Johannes
    Stoll, Richard
    Stachniss, Vitus
    Pieper, Klaus
    ODONTOLOGY, 2011, 99 (01) : 55 - 61