P and R Wave Detection in Complete Congenital Atrioventricular Block

被引:0
作者
J. Guerrero
M. Martínez
R. Magdalena
J. Muñoz
M. Bataller
A. Rosado
J. V. Francés
J. Chorro
机构
[1] University of Valencia,Digital Signal Processing Group, Department of Electronic Engineering
[2] University Clinic Hospital,Service of Cardiology
来源
Annals of Biomedical Engineering | 2009年 / 37卷
关键词
Complete congenital atrioventricular block; P and R wave detection; QRS; Adaptive impulse correlated filter; SNEO;
D O I
暂无
中图分类号
学科分类号
摘要
Complete atrioventricular block (type III AVB) is characterized by an absence of P wave transmission to ventricles. This implies that QRS complexes are generated in an autonomous way and are not coordinated with P waves. This work introduces a new algorithm for the detection of P waves for this type of pathology using noninvasive electrocardiographic surface leads. The proposed algorithm is divided into three stages. In the first stage, the R waves located by a QRS detector are used to generate the RR series and time references for the other stages of the algorithm. In the second stage, the ventricular activity (QT segment) is removed by using an adaptive filter that obtains an averaged pattern of the QT segment. In the third stage, a new P wave detector is applied to the residual signal obtained after QT cancellation in order to detect P wave locations and get the PP time series. Eight Holter records from patients with congenital type III AVB were used to verify the proposed algorithm. Although further improvements should be made to improve the algorithm’s performance, the results obtained show high average values of sensitivity (90.52%) and positive prediction (90.98%).
引用
收藏
页码:94 / 106
页数:12
相关论文
共 86 条
[1]  
Abboud S.(1990)Quantification of the fetal electrocardiogram using averaging technique Comput. Biol. Med. 20 147-155
[2]  
Barkai G.(1999)A new adaptive scheme for ECG enhancement Signal. Process. 75 253-263
[3]  
Mashiach S.(1995)Análisis espectral de la variabilidad de la frecuencia cardíaca en el bloqueo A-V completo de origen congénito Rev. Lat. Cardiol 16 12-18
[4]  
Sadeh D.(2007)Development of gradient descent adaptive algorithms to remove common mode artifact for improvement of cardiovascular signal quality Ann. Biomed. Eng. 35 1146-1155
[5]  
Almenar V.(1982)Fetal electrocardiogram enhancement by time-sequenced adaptive filtering IEEE Trans. Biomed. Eng. 29 458-460
[6]  
Albiol A.(2006)A new algorithm for foetal QRS detection in surface abdominal records Comput. Cardiol. 33 441-444
[7]  
Chorro F. J.(1998)Esophageal PP intervals for analysis of short-term heart rate variability in patients with atrioventricular block before and after insertion of a temporary ventricular inhibited pacemaker Int. J. Cardiol. 64 271-276
[8]  
Guerrero J. F.(1991)Alignment methods for averaging of high-resolution cardiac signals: a comparative study of performance IEEE Trans. Biomed. Eng. 38 571-579
[9]  
Calpe J.(2004)Averaging algorithm based on data statistics in magnetocardiography Neurol. Clin. Neurophysiol. 2004 42-1044
[10]  
Dalli E.(1992)Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques IEEE Trans. Biomed. Eng. 39 1032-73