Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging

被引:0
|
作者
Amir Seginer
Rita Schmidt
机构
[1] Siemens Healthcare Ltd,Department of Brain Sciences
[2] Weizmann Institute of Science,The Azrieli National Institute for Human Brain Imaging and Research
[3] Weizmann Institute of Science,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Magnetic resonance imaging (MRI) is a powerful and versatile technique that offers a range of physiological, diagnostic, structural, and functional measurements. One of the most widely used basic contrasts in MRI diagnostics is transverse relaxation time (T2)-weighted imaging, but it provides only qualitative information. Realizing quantitative high-resolution T2 mapping is imperative for the development of personalized medicine, as it can enable the characterization of diseases progression. While ultra-high-field (≥ 7 T) MRI offers the means to gain new insights by increasing the spatial resolution, implementing fast quantitative T2 mapping cannot be achieved without overcoming the increased power deposition and radio frequency (RF) field inhomogeneity at ultra-high-fields. A recent study has demonstrated a new phase-based T2 mapping approach based on fast steady-state acquisitions. We extend this new approach to ultra-high field MRI, achieving quantitative high-resolution 3D T2 mapping at 7 T while addressing RF field inhomogeneity and utilizing low flip angle pulses; overcoming two main ultra-high field challenges. The method is based on controlling the coherent transverse magnetization in a steady-state gradient echo acquisition; achieved by utilizing low flip angles, a specific phase increment for the RF pulses, and short repetition times. This approach simultaneously extracts both T2 and RF field maps from the phase of the signal. Prior to in vivo experiments, the method was assessed using a 3D head-shaped phantom that was designed to model the RF field distribution in the brain. Our approach delivers fast 3D whole brain images with submillimeter resolution without requiring special hardware, such as multi-channel transmit coil, thus promoting high usability of the ultra-high field MRI in clinical practice.
引用
收藏
相关论文
共 50 条
  • [21] In vivo quantitative MRI: T1 and T2 measurements of the human brain at 0.064 T
    Jordanova, Kalina V. V.
    Martin, Michele N. N.
    Ogier, Stephen E. E.
    Poorman, Megan E. E.
    Keenan, Kathryn E. E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (03) : 487 - 498
  • [22] In vivo quantitative MRI: T1 and T2 measurements of the human brain at 0.064 T
    Kalina V. Jordanova
    Michele N. Martin
    Stephen E. Ogier
    Megan E. Poorman
    Kathryn E. Keenan
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 487 - 498
  • [23] High-Resolution 7T MRI of the Human Hippocampus In Vivo
    Thomas, Bradley P.
    Welch, E. Brian
    Niederhauser, Blake D.
    Whetsell, William O., Jr.
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    Creasy, Jeffrey L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1266 - 1272
  • [24] Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
    Liu, Jiaen
    van Gelderen, Peter
    de Zwart, Jacco A.
    Duyn, Jeff H.
    NEUROIMAGE, 2020, 206
  • [25] MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences
    Seitz, J
    Held, P
    Strotzer, M
    Völk, M
    Nitz, WR
    Dorenbeck, U
    Stamato, S
    Feuerbach, S
    ACTA RADIOLOGICA, 2002, 43 (04) : 349 - 353
  • [26] High-resolution isotropic 3D diffusion tensor Imaging of the human brain
    Golay, X
    Jiang, H
    van Zijl, PCM
    Mori, S
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 837 - 843
  • [27] High-resolution and fast 3D ultrasonic imaging technique
    Benenson, ZM
    Elizarov, AB
    Yakovleva, TV
    O'Brien, WD
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1561 - 1564
  • [28] Fast high-resolution T1 mapping of the human brain
    Deichmann, R
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 20 - 27
  • [29] The application of paramagnetic contrast-based T2 effect to 3D heavily T2W high-resolution MR imaging of the brachial plexus and its branches
    Wang, Lixia
    Niu, Yanfeng
    Kong, Xiangquan
    Yu, Qun
    Kong, Xiangchuang
    Lv, Yinzhang
    Shi, Heshui
    Li, Chungao
    Wu, Wenjun
    Wang, Bing
    Liu, Dingxi
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (03) : 578 - 584
  • [30] Correcting for imaging gradients-related bias of T2 relaxation times at high-resolution MRI
    Bnaiahu, Natalie
    Omer, Noam
    Wilczynski, Ella
    Levy, Shir
    Blumenfeld-Katzir, Tamar
    Ben-Eliezer, Noam
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1806 - 1817