Reproducibility of technetium-99m ethylenedicysteine clearance

被引:0
|
作者
Levent Kabasakal
Metin Halaç
Ebru Alkan
Nihat Özçelik
I. lhami Uslu
机构
[1] Cerrahpas,
[2] a Medical Faculty,undefined
[3] Department of Nuclear Medicine,undefined
[4] Istanbul,undefined
[5] Turkey,undefined
来源
关键词
Key words: Radionuclide renography; Renal function; Technetium-99m ethylenedicysteine; Effective renal plasma flow;
D O I
暂无
中图分类号
学科分类号
摘要
It has been shown that technetium-99m ethylenedicysteine (99mTc-EC) clearance displays a strong correlation with orthoiodohippurate clearance and that it is possible to estimate effective renal plasma flow from 99mTc-EC clearance. However, in routine practice, when monitoring renal function of patients by clearance determinations it is imperative to test the reproducibility of the clearance technique in order to decide whether the changes in renal function are related to disease or not. The aim of this study was to test the reproducibility of 99mTc-EC clearance. The study group comprised 13 patients aged between 24 and 58 years (eight female and five male). Two patients had single kidneys due to agenesis and hypoplasia. Plasma creatinine and BUN levels were within the normal range and remained stable between two clearance studies. None of the patients were receiving medication. Two separate multiple sample clearance studies were performed in each patient within a week. The difference between two studies was expressed as a percentage of the mean value of the two studies, and the standard deviation of these percentages represented the precision. The plasma clearance of 99mTc-EC in the first-step studies ranged from 190 ml/min to 561 ml/min with a mean of 411±101 ml/min. The clearances obtained from the second-step studies ranged from 248 ml/min to 552 ml/min, with a mean of 387±94 ml/min. There was no statistically significant difference between the two clearance studies (P>0.05). There was a mean difference of 5.3% between the first and second clearance studies, and the precision was found to be 12.7%. In conclusion, this study suggested that consecutive 99mTc-EC clearance measurements should be interpreted cautiously.
引用
收藏
页码:900 / 902
页数:2
相关论文
共 50 条
  • [1] Reproducibility of technetium-99m ethylenedicysteine clearance
    Kabasakal, L
    Halaç, M
    Alkan, E
    Özçelik, N
    Uslu, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (08) : 900 - 902
  • [2] Reproducibility of technetium-99m ethylenedicysteine clearance
    Cerrahpaşa Medical Faculty, Department of Nuclear Medicine, Istanbul, Turkey
    不详
    Eur. J. Nucl. Med. Mol. Imaging, 8 (900-902):
  • [3] Reproducibility of technetium-99m mercaptoacetyltriglycine clearance
    Piepsz, A
    Tondeur, M
    Kinthaert, J
    Ham, HR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (02): : 195 - 198
  • [4] Reassessment of the reproducibility of Technetium-99m mercaptoacetyltriglycine renal clearance
    De Sadeleer, Carlos
    Tondeur, Marianne
    Georges, Bernard
    Ham, Hamphrey R.
    Piepsz, Amy
    NUCLEAR MEDICINE REVIEW, 2005, 8 (01) : 15 - 20
  • [5] Reproducibility of Tc-99m ethylenedicysteine clearance
    Kabasakal, L
    Halaç, M
    Alkan, E
    Özçelik, N
    Önsel, Ç
    Uslu, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1041 - 1041
  • [6] Reproducibility of technetium-99m mercaptoacetyltriglycine clearance in patients with impaired renal function
    Erdil, TY
    Dede, F
    Tuglular, S
    Sen, F
    Ones, T
    Farsakoglu, Z
    Inanir, S
    Ozener, C
    Akoglu, E
    Turoglu, T
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (02) : 191 - 196
  • [7] Simplified determination of technetium-99m ethylenedicysteine clearance from a single plasma sample: What is the upper normal range?
    Kabasakal, L
    Onsel, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (11): : 1556 - 1556
  • [8] Simplified determination of technetium-99m ethylenedicysteine clearance from a single plasma sample: What is the upper normal range
    Cerrahpaşa Medical Faculty, Department of Nuclear Medicine, TR-34303 Aksaray Istanbul, Turkey
    Eur. J. Nucl. Med. Mol. Imaging, 11 (1556):
  • [9] STIMULATED SALIVARY CLEARANCE OF TECHNETIUM-99M PERTECHNETATE
    BLUE, PW
    JACKSON, JH
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (03) : 308 - 311
  • [10] Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes
    Rainer Bartosch
    Susanne Granegger
    Helmut Sinzinger
    European Journal of Nuclear Medicine, 1998, 25 : 1333 - 1335