Experimental investigation of a novel solar air heater based on heat pipe vacuum tube collector integrated with finned-tube heat exchanger

被引:0
作者
Anshul Sachdeva
M. Chandrashekara
Avadhesh Yadav
机构
[1] National Institute of Technology Kurukshetra,Department of Mechanical Engineering
[2] National Institute of Solar Energy,undefined
来源
Journal of Thermal Analysis and Calorimetry | 2023年 / 148卷
关键词
Solar air heater; Heat pipe vacuum tube; Header; Finned-tube heat exchanger; Sensible heat storage; Thermal analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The study intends to analyze the thermal performance of a novel solar air heater based on heat pipe vacuum tube solar collector and finned-tube heat exchanger. The solar collector has been introduced with a new header where heat transfer fluid (Therminol-55) gains heat directly in contact with the condenser section of the heat pipe. This eliminates thermal paste application between the condenser and manifold in the existing systems. The system's thermal performance has been experimentally evaluated using two different (four-row and eight-row) finned-tube heat exchangers at four varied air flow rates, viz. 100 kg h–1, 400 kg h–1, 700 kg h–1 and 1000 kg h–1. The system with eight-row heat exchanger performed better than the four-row heat exchanger at each air flow rate. 100 kg h–1 resulted in a maximum rise in temperature of air (55.4 °C) and maximum outlet temperature of air (89.4 °C). Meanwhile, the maximum energy and exergy efficiency of 95.7% and 2.17% were observed at 1000 kg h–1. The maximum effectiveness of the four and eight-row heat exchangers was found as 70.7% and 79.4%, respectively, at 100 kg h–1. The monthly cost saving by utilization of the proposed system is 65.65 $, and the payback period is 12.4 months. The amount of CO2 averted from releasing into the atmosphere is 787.7 kg per month. The results suggest the utility of the proposed solar air heater as an environment-friendly replacement for conventional air heaters for consistent operation in the daytime. The experimental study was performed at the campus of NIT Kurukshetra, India (29.9476°N, 76.8155°E).
引用
收藏
页码:10917 / 10936
页数:19
相关论文
共 96 条
  • [1] Solangi KH(2011)A review on global solar energy policy Renew Sustain Energy Rev 15 2149-2163
  • [2] Islam MR(2019)Experimental investigation of a double pass converging finned wire mesh packed bed solar air heater J Energy Storage 21 713-723
  • [3] Saidur R(2022)Current status and prospect of integrating solar air heating systems for drying in various sectors and industries Sustain Energy Technol Assess 52 102274-581
  • [4] Rahim NA(2022)An updated review on solar air heating systems Sustain Energy Technol Assess 53 102573-6660
  • [5] Fayaz H(2003)The performance of a solar air heater with conical concentrator under forced convection Int J Therm Sci 42 571-275
  • [6] Singh S(2011)Performance of solar air heater ducts with different types of ribs on the absorber plate Energy 36 6651-86
  • [7] Dhruw L(2004)Development and testing of a solar air-heater with conical concentrator Renew Energy 29 263-46
  • [8] Chander S(2020)Performance enhancement of a greenhouse dryer: analysis of a cost-effective alternative solar air heater J Clean Prod 251 877-467
  • [9] Lingayat A(2016)Energy and exergy evaluation of an integrated solar heat pipe wall system for space heating Sadhana Acad Proc Eng Sci 41 1839-50
  • [10] Zachariah R(2018)Experimental study on the thermal efficiency of the forced convection evacuated tube solar air collectors with and without absorber plate J Indus Pollut Control 34 447-45