Voltammetric sensor for nitrite determination based on its electrocatalytic reduction at the surface of p-duroquinone modified carbon paste electrode

被引:0
作者
Jahan Bakhsh Raoof
Reza Ojani
Maryam Ramine
机构
[1] Mazandaran University,Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Science
来源
Journal of Solid State Electrochemistry | 2009年 / 13卷
关键词
-Duroquinone; Tetramethyl-; -benzoquinone; Carbon paste electrode; Nitrite; Electrocatalysis; Cyclic voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
A p-duroquinone (tetramethyl-p-benzoquinone) modified carbon paste electrode (DMCPE) was employed to study the electrocatalytic reduction of nitrite in aqueous solutions using cyclic voltammetry (CV), double potential-step chronoamperometry, and differential pulse voltammetry (DPV). It has found that under an optimum condition (pH 1.00), the reduction of nitrite at the surface of DMCPE occurs at a potential of about 660 mV less negative than that of an unmodified carbon paste electrode (CPE). The catalytic rate constant, k′h, based on Andrieux and Saveant theoretical model was calculated as \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$k'_h = 4.56 \times 10^{ - 5} \,cm\,s^{ - 1} $$\end{document} for scan rate 10 mV s-1. Also, the apparent diffusion coefficient, Dapp, was found as 2.5 × 10–10 and 3.61 × 10–5 cm2 s-1for p-duroquinone in carbon paste matrix and nitrite in aqueous buffered solution, respectively. The values for αnα were estimated to be −0.65 and −0.19 for the reduction of nitrite at the surface of DMCPE and CPE, respectively. The electrocatalytic reduction peak currents showed a linear dependence on the nitrite concentration, and a linear analytical curve was obtained in the ranges of 5.0 × 10–5 M to 8.0 × 10–3 M and 6.0 × 10–6 M to 8.0 × 10–4 M of nitrite concentration with CV and DPV methods, respectively. The detection limits (2σ) were determined as 2.5 × 10–5 M and 4.3 × 10–6 M by CV and DPV methods. This method was also applied as a simple, selective and precise method for determination of nitrite in real samples (the weak liquor from the wood and paper factory of Mazandaran province in Iran) by using a standard addition method.
引用
收藏
页码:1311 / 1319
页数:8
相关论文
共 162 条
  • [1] Braida W(2000)undefined Water Air Soil Pollut 118 13-undefined
  • [2] Ong SK(2005)undefined Coord Chem Rev 249 485-undefined
  • [3] Carlsen CU(2002)undefined Chem Rev 102 1167-undefined
  • [4] Moller JKS(2006)undefined Meat Sci 72 206-undefined
  • [5] Skibsted LH(1970)undefined Nature 225 21-undefined
  • [6] Moller JKS(1972)undefined Science 177 15-undefined
  • [7] Skibsted LH(1980)undefined Analyst 105 241-undefined
  • [8] Yetim H(2005)undefined Biochem 70 473-undefined
  • [9] Kayacier A(1999)undefined Anal Chim Acta 387 1-undefined
  • [10] Kesmen Z(2000)undefined J Chromatogr B 744 433-undefined