Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogram

被引:0
作者
C. Grönlund
N. Östlund
K. Roeleveld
J. S. Karlsson
机构
[1] University Hospital,Department of Biomedical Engineering & Informatics
[2] Umeå University,Centre for Biomedical Engineering and Physics
[3] Department of Rehabilitation Medicine,Human Movement Sciences Program
[4] Faculty of Health Sciences,undefined
[5] Norwegian University of Science & Technology,undefined
来源
Medical and Biological Engineering and Computing | 2005年 / 43卷
关键词
Surface electromyography; EMG; Multichannel; Conduction velocity; Fibre orientation; Motor unit;
D O I
暂无
中图分类号
学科分类号
摘要
The paper presents a new approach for simultaneous estimation of muscle fibre conduction velocity (MFCV) and muscle fibre orientation (MFO) for motor units (MUs) in two-dimensional (2D) multichannel surface electromyography recordings. This is an important tool for detecting changes and abnormalities in muscle function and structure. In addition, simultaneous estimation of MFO and MFCV avoids the necessity of manual electrode alignment. The proposed method detected propagating MU action potentials (MUAPs) in a running time window as moving components in amplitude maps. Thereafter, estimations were obtained by fitting a three-dimensional function to these maps. The performance was evaluated using synthetic MU signals at 10 dB SNR and authentic biceps brachii measurements. Results demonstrated MFCV and MFO estimates with standard deviations of less than 0.05 m s−1 and 1° for simulated signals, and less than 0.2 m s−1 and 4° for experimental data. However, standard deviations as low as 0.12 m s−1 and 1.6° from real signals were demonstrated. It was concluded that the method performs as well as, or better than, linear array multichannel methods when individual propagating MUAPs can be identified, even if electrodes are not aligned with fibre direction.
引用
收藏
页码:63 / 70
页数:7
相关论文
共 81 条
[1]  
Andreassen S.(1987)Muscle fibre conduction velocity in motor units of the human anterior tibialis muscle: a new size principle Physiol. 391 561-571
[2]  
Arendt-Nielsen L.(1968)L1 approximation and the analysis of data Appl. Stat. 17 51-57
[3]  
Barrodale J.(2002)Correlation between fiber conduction velocity and fiber diameter Clin. Neurophysiol. 113 S39-S39
[4]  
Blijham P. J.(2004)Muscle-fiber conduction velocity and electromyography as diagnostic tools in patients with suspected inflammatory myopathy: a prospective study Muscle Nerve 29 46-50
[5]  
Van Engelen B. G. M.(1990)Conduction velocity along muscle fibers Arch. Phys. Med. Rehabil. 71 558-561
[6]  
Zwarts M. J.(1888) in Duchenne muscular dystrophy Phil. Mag. (5th Ser.) 25 184-191
[7]  
Blijham P. J.(2000)On a new method of reducing observations relating to several quantiles J. Electromyogr. Kinesiol. 10 337-349
[8]  
Hengstman G. J.(2001)Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions IEEE Trans. Biomed. Eng. 48 637-646
[9]  
Ter Laak H. J.(2001)A novel approach for precise simulation of the EMG signal detected by surface electrodes Med. Biol. Eng. Comput. 39 225-236
[10]  
Van Engelen B. G.(2004)Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays Muscle Nerve 29 282-291