Surface porous fibre-reinforced composite bulk bone substitute.

被引:21
|
作者
Aho A.J. [1 ]
Hautamäki M. [1 ]
Mattila R. [1 ]
Alander P. [1 ]
Strandberg N. [1 ]
Rekola J. [1 ]
Gunn J. [1 ]
Lassila L.V. [1 ]
Vallittu P.K. [1 ]
机构
[1] Department of Prosthetic Dentistry and Biomaterials Research, Institute of Dentistry, University of Turku, Turku
关键词
Artificial bone; Bioactive glass; Biomechanics; Bone healing; Fibre-reinforcement; Polymethylmetacrylate Prosthesis;
D O I
10.1007/s10561-004-0214-0
中图分类号
学科分类号
摘要
The aim of this study was to describe and evaluate the significance of a porous surface with bioactive glass granules (S53P4) covering an artificial bulk material based on polymethylmetacrylate (PMMA) and fibre-reinforced composite (FRC) technology. Effort was focused particularly on characters of the porous surface and biomechanical properties of the material in vitro , and test in vivo the implant in reconstruction in an experimental long bone segment defect model. The defect, 10 mm in length, created in the shaft of rabbit tibia, was reconstructed by the implant and fixed by intramedullary K-wires. The implant was incorporated within 4 weeks by new bone growth from the host bone covering particularly its posterior surface and cortex/implant junctions with bridging trabecular bone. Later, at 8 weeks, new bone was found also at the cortex/implant interface and in the medullary canal of the implant. Histometric measurements revealed direct bone/implant surface contact in 34% at the interface. Bioactive glass granules in the porous surface evoked the most direct contact with bone. The implants manufactured from PMMA only served as a control group, and showed significantly lower osteoconductive properties. Biomechanical measurements in vitro of fibre-reinforced PMMA specimens revealed values for bending strength and the flexural modulus to match them to human bone. This artificial bulk bone material based on PMMA/FRC technology seems to have proposing properties to be used as a bone substitute on load-bearing conditions.
引用
收藏
页码:213 / 221
页数:8
相关论文
共 50 条
  • [31] Buckling of thin skew fibre-reinforced composite laminates
    Wang, S
    THIN-WALLED STRUCTURES, 1997, 28 (01) : 21 - 41
  • [32] STRESS-STRAIN CURVE OF A FIBRE-REINFORCED COMPOSITE
    KELLY, A
    LILHOLT, H
    PHILOSOPHICAL MAGAZINE, 1969, 20 (164): : 311 - &
  • [33] Analysis and optimum design of fibre-reinforced composite structures
    G. Kovács
    A.A. Groenwold
    K. Jármai
    J. Farkas
    Structural and Multidisciplinary Optimization, 2004, 28 : 170 - 179
  • [35] INTERFACIAL TRACTIONS IN A FIBRE-REINFORCED ELASTIC COMPOSITE MATERIAL
    SMITH, GE
    SPENCER, AJM
    JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 1970, 18 (02) : 81 - +
  • [36] Natural Fibre-Reinforced Composite for Ballistic Applications: A Review
    Kazeem Olabisi Odesanya
    Roslina Ahmad
    Mohammad Jawaid
    Sedat Bingol
    Ganiyat Olusola Adebayo
    Yew Hoong Wong
    Journal of Polymers and the Environment, 2021, 29 : 3795 - 3812
  • [37] On the Elastic Properties of Some Fibre-Reinforced Composite Structures
    Teodorescu-Draghicescu, Horatiu
    Vlase, Sorin
    Chiru, Anghel
    Scutaru, Maria Luminita
    Popa, Ionatan
    ADVANCES IN MANUFACTURING ENGINEERING, QUALITY AND PRODUCTION SYSTEMS, VOL II, 2009, : 445 - 448
  • [38] Fibre-Reinforced Composite for Protection against Shark Bites
    Fiedler, Thomas
    Verstegen, Trent
    MATERIALS, 2020, 13 (22) : 1 - 11
  • [39] SiC fibre-reinforced Ti-based composite
    Lu, YX
    Li, DX
    Shi, NL
    Ma, ZY
    Bi, J
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 1996, 6 (04) : 72 - 75
  • [40] Assessment of failure criteria for fibre-reinforced composite laminates
    Univ of the Witwatersrand, South Africa
    Int J Fatigue, 7 (513-518):