A Magnetometer Based on a Hall-Effect Transducer

被引:0
|
作者
I. O. Orobei
I. F. Kuz'mitskii
D. A. Grinyuk
S. E. Zharskii
V. V. Saroka
M. V. Maksimova
机构
[1] Belarussian State Technological University,
来源
Instruments and Experimental Techniques | 2003年 / 46卷
关键词
Magnetic Field; Physical Chemistry; Relative Error; Temperature Measurement; Signal Suppression;
D O I
暂无
中图分类号
学科分类号
摘要
An induction meter based on a Hall-effect transducer with in-phase signal suppression and thermostabilization circuits is described. It is powered by a 103-Hz ac line. The maximum relative error in temperature measurements from 0 to 70°C does not exceed 0.7 % for magnetic fields of 50–100 μT, 0.4% for 0.1–1 mT, and 0.1% for 1–625 mT. In the range of 50–500 μT, the error is determined by an in-phase signal. The contribution of the total temperature error is ≤0.01% per 50°C. Depending on the induction of the measured magnetic field, the resolution changes from 0.12 to 19 μT.
引用
收藏
页码:271 / 274
页数:3
相关论文
共 50 条
  • [1] A magnetometer based on a hall-effect transducer
    Orobei, IO
    Kuz'mitskii, IF
    Grinyuk, DA
    Zharskii, SE
    Saroka, VV
    Maksimova, MV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (02) : 271 - 274
  • [2] HALL-EFFECT MAGNETOMETER FOR RELATIVE MEASUREMENTS
    VASILEV, MP
    GORELKIN, AS
    MOZIN, IV
    LUZHANSKII, SM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (04): : 1199 - +
  • [3] TRANSDUCER OF TRIPHASIC POWER WITH HALL-EFFECT
    CAINI, V
    VANNUCCHI, G
    ELETTROTECNICA, 1979, 66 (12): : 1011 - 1012
  • [4] Hall-Effect sensor positional transducer
    Avizzano, CA
    Ferrazzin, D
    Prisco, GM
    Bergamasco, M
    SENSOR FUSION AND DECENTRALIZED CONTROL IN ROBOTIC SYSTEMS II, 1999, 3839 : 318 - 327
  • [5] HALL-EFFECT TRANSDUCER FOR APEXCARDIOGRAPHY AND SPHYGMOGRAPHY
    NALECZ, M
    HOFFMAN, M
    MANIEWSKI, R
    NOWICKA, J
    RYDLEWSKASADOWSKA, W
    TARLOWSKI, A
    JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (04): : 313 - 318
  • [6] MEASUREMENT OF NICKEL FILMS USING A HALL-EFFECT MAGNETOMETER
    REEBER, MD
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (08) : C324 - C324
  • [7] ELECTRONIC PROCESSING OF TRANSDUCER SIGNALS - HALL-EFFECT AS AN EXAMPLE
    COOPER, AR
    BRIGNELL, JE
    SENSORS AND ACTUATORS, 1985, 7 (03): : 189 - 198
  • [8] MAGNETOMETER BASED ON HALL EFFECT
    VIEHMANN, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (05): : 537 - &
  • [9] LINEAR POSITION TRANSDUCER USING A MAGNET AND HALL-EFFECT DEVICES
    MCCALL, WD
    ROHAN, EJ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1977, 26 (02) : 133 - 136
  • [10] APPLICATION OF A HALL-EFFECT TRANSDUCER FOR MEASUREMENT OF TENDON STRAINS IN HORSES