Native T1 mapping to detect extent of acute and chronic myocardial infarction: comparison with late gadolinium enhancement technique

被引:0
作者
Amardeep Ghosh Dastidar
Iwan Harries
Giulia Pontecorboli
Vito D. Bruno
Estefania De Garate
Charlie Moret
Anna Baritussio
Thomas W. Johnson
Elisa McAlindon
Chiara Bucciarelli-Ducci
机构
[1] University Hospitals Bristol NHS Trust,Bristol Heart Institute
[2] University Hospitals Bristol and University of Bristol,NIHR Bristol Cardiovascular Biomedical Research Centre, Bristol Heart Institute
[3] University of Bristol,Translational Health Sciences, Bristol Medical School
来源
The International Journal of Cardiovascular Imaging | 2019年 / 35卷
关键词
Viability; T1 mapping; Cardiovascular magnetic resonance; Myocardial infarction;
D O I
暂无
中图分类号
学科分类号
摘要
Investigate whether native-T1 mapping can assess the transmural extent of myocardial infarction (TEI) thereby differentiating viable from non-viable myocardium without the use of gadolinium-contrast in both acute and chronic myocardial infarction (aMI and cMI). Sixty patients (30 cMI > 1 year and 30 aMI day 2 STEMI) and 20 healthy-controls underwent 1.5 T CMR to assess left ventricular function (cine), native-T1 mapping (MOLLI sequence 5(3)3, motion-corrected) and the presence and TEI from late gadolinium enhancement (LGE) images. Segments with TEI > 75% was considered non-viable. Gold-standard LGE-TEI was compared with corresponding segmental native-T1. Segmental native-T1 correlated significantly with TEI (R = 0.74, p < 0.001 in cMI and R = 0.57, p < 0.001 in aMI). Native-T1 differentiated segments with no LGE (1031 ± 31 ms), LGE positive but viable (1103 ± 57 ms) and LGE positive but non-viable (1206 ± 118 ms) in cMI (p < 0.01). It also differentiated segments with no LGE (1054 ± 65 m), LGE positive but viable (1135 ± 73 ms) and LGE positive but non-viable (1168 ± 71 ms) in aMI (p < 0.01). ROC analysis demonstrated excellent accuracy of native-T1 mapping compared to LGE-TEI (AUC − 0.88, p < 0.001 in cMI, vs AUC − 0.83, p < 0.001 in aMI). Native-T1 performed better in cMI than aMI (p < 0.01). In cMI a segmental T1 threshold of 1085 ms differentiated viable from non-viable segments with a sensitivity 88% and specificity of 88% whereas a T1 of 1110 ms differentiated viable from nonviable with 79% sensitivity and 79% specificity in aMI. Native-T1 mapping correlates significantly with TEI thereby differentiating between normal, viable, and non-viable myocardium with distinctive T1 profiles in aMI and cMI. Native T1-mapping to detect MI performed better in cMI compared to aMI due to absence of myocardial oedema. Native-T1 mapping holds promise for viability assessment without the need for gadolinium-contrast agent.
引用
收藏
页码:517 / 527
页数:10
相关论文
共 127 条
[1]  
Romero J(2012)CMR imaging assessing viability in patients with chronic ventricular dysfunction due to coronary artery disease: a meta-analysis of prospective trials JACC Cardiovasc Imaging 5 494-508
[2]  
Xue X(2016)MRI in the assessment of ischaemic heart disease Heart 102 165-167
[3]  
Gonzalez W(2000)The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction N Engl J Med 343 1445-1453
[4]  
Garcia MJ(1999)Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function Circulation 100 1992-2002
[5]  
Dastidar AG(2015)Residual or retained gadolinium: practical implications for radiologists and our patients Radiology 275 630-634
[6]  
Rodrigues JCL(2015)Myocardial T1 mapping Circ J 79 487-494
[7]  
Baritussio A(2015)Native T1 Mapping by 3-T CMR imaging for characterization of chronic myocardial infarctions JACC Cardiovasc Imaging 8 1019-1030
[8]  
Bucciarelli-Ducci C(2012)Third universal definition of myocardial infarction Eur Heart J 33 2551-2567
[9]  
Kim RJ(2015)Quantification of infarct size and myocardium at risk: evaluation of different techniques and its implications Eur Heart J Cardiovasc Imaging 16 738-746
[10]  
Wu E(1996)“Black blood” T2-weighted inversion-recovery MR imaging of the heart Radiology 199 49-57