Shocks after implantable cardioverter-defibrillator implantation in idiopathic cardiomyopathy patients: a myocardial biopsy study

被引:0
作者
Erdal Safak
Giuseppe D´Ancona
Heinz-Peter Schultheiss
Uwe Kühl
Stephan Kische
Hilmi Kaplan
Hüseyin Ince
Jasmin Ortak
机构
[1] Vivantes Klinikum Im Friedrichshain Und Am Urban,Department of Cardiology
[2] Rostock University Medical Center,undefined
[3] Universitätsmedizin Charité Berlin,undefined
来源
Heart and Vessels | 2018年 / 33卷
关键词
Myocardial; Biopsy; Inflammation; ICD; Fibrosis; Shock;
D O I
暂无
中图分类号
学科分类号
摘要
Prediction of follow-up shock is crucial to stratify patients with dilated cardiomyopathy (DCM) requiring implantable cardioverter defibrillator (ICD). The objective of the article is to assess the predictive value of endo-myocardial biopsy (EMB) towards ICD shock and follow-up mortality. A series of patients with DCM scheduled for ICD implantation underwent EMB to further determine the genesis of DCM. Presence of fibrosis and inflammation was documented and related to outcomes. A total of 240 patients were referred for ICD as primary (56%) and secondary (44%) prophylaxis. EMB showed myocardial fibrosis in 55.4%, inflammation in 55.7%, and viral genomic material in 60%. Median follow-up was 39 months (1–209). Appropriate and inappropriate shocks occurred in 29.2 and 20.4%. At logistic regression, determinants of appropriate shock were ICD indication for secondary prophylaxis (direct relationship: p = 0.009, OR 3.4, CI 1.3–8.8) and presence of inflammation at EMB (inverse relationship: p = 0.04, OR 0.4, CI 0.1–0.9). Moreover, the sole determinant of inappropriate shock was age at implant (inverse relationship: p = 0.003, OR = 0.9, CI 0.90–0.98). Overall mean estimated survival was 168 months and 5-year survival was 83%. Degree of improvement in LVEF% was the sole determinant of follow-up mortality (inverse relationship p = 0.02; HR = 0.9; CI 0.88–0.99). Present selection criteria for ICDs implant rely mainly on LVEF% that lacks sensitivity and specificity. EMB can identify the substrate of increased or reduced life-threatening arrhythmias. Presence of inflammation is a positive prognostic factor for reduced arrhythmogenic risk, independently by the ICD implantation indication.
引用
收藏
页码:205 / 211
页数:6
相关论文
共 231 条
[1]  
Strickberger SA(2003)Amiodarone versus implantable cardioverter- defibrillator: randomized trial in patients with nonischemic dilated cardiomyopathy and asymptomatic nonsustained ventricular tachycardia—AMIOVIRT J Am Coll Cardiol 41 1707-1712
[2]  
Hummel JD(2004)Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy N Engl J Med 350 2151-2158
[3]  
Bartlett TG(2005)Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure N Engl J Med 352 225-237
[4]  
Frumin HI(2002)Primary prevention of sudden cardiac death in idiopathic dilated cardiomyopathy: the cardiomyopathy trial (CAT) Circulation 105 1453-1458
[5]  
Schuger CD(2016)Defibrillator implantation in patients with nonischemic systolic heart failure N Engl J Med 375 1221-1230
[6]  
Beau SL(2016)Proposal for a revised definition of dilated cardiomyopathy, hypokinetic non-dilated cardiomyopathy, and its implications for clinical practice: a position statement of the ESC working group on myocardial and pericardial diseases Eur Heart J 37 1850-1858
[7]  
Bitar C(2005)High prevalence of viral genomes and multiple viral infections in the myocardium of adults with “idiopathic” left ventricular dysfunction Circulation 111 887-893
[8]  
Morady F(2013)Association of fibrosis with mortality and sudden cardiac death in patients with nonischemic dilated cardiomyopathy JAMA 309 896-908
[9]  
Kadish A(2008)Late gadolinium enhancement by cardiovascular magnetic resonance heralds an adverse prognosis in nonischemic cardiomyopathy J Am Coll Cardiol 51 2414-2421
[10]  
Dyer A(2011)Use of cardiovascular magnetic resonance for risk stratification in chronic heart failure: prognostic value of late gadolinium enhancement in patients with non-ischaemic dilated cardiomyopathy Heart 97 727-732