Imaging a microfocus X-ray focal spot with a thin coded aperture

被引:0
|
作者
Graham R. Davis
Thomas Beckenbach
Pascal Meyer
机构
[1] Queen Mary University of London,Institute of Dentistry
[2] Microworks GmbH,Institute of Microstructure Technology
[3] Karlsruhe Institute of Technology,undefined
来源
Scientific Reports | / 12卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Imaging of the focal spot size in X-ray generators can be achieved by means of a pinhole in a highly attenuating material, such as gold. For microfocus generators with spot sizes of only around 10 microns or less, the material must be very thin to avoid an impractical aspect ratio. With a 90 kV source, only 11% attenuation is attained with 5 µm gold. For a pinhole that is smaller than the focal spot, the signal-to-noise ratio (SNR) may be less than 1. To image the focal spot of a medical X-ray generator, a coded aperture has been used previously to reduce the exposure time required, however the same technique does not appear to have been used to increase the SNR when the attenuation is very low. Such a method is used here, using a no-two-holes-touching variation of a modified uniformly redundant array (MURA). In a prototype sample, with only 5 µm gold having 2.75 µm holes, the focal spot of a microfocus X-ray generator used in a micro-CT system could be clearly visualised and quantified. Directionality of the aberrations made focussing of the X-ray spot more intuitive and reduced the time required to obtain an optimal, quantifiable focus.
引用
收藏
相关论文
共 50 条
  • [1] Imaging a microfocus X-ray focal spot with a thin coded aperture
    Davis, Graham R.
    Beckenbach, Thomas
    Meyer, Pascal
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] X-ray imaging inside the focal spot of polycapillary optics using the coded aperture concept
    Dabrowski, K. M.
    Dul, D. T.
    Korecki, P.
    OPTICS EXPRESS, 2013, 21 (03): : 2920 - 2927
  • [3] AN INVESTIGATION OF THE FOCAL SPOT SIZE IN A MICROFOCUS X-RAY TUBE
    GRIDER, DE
    AUSBURN, PK
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1987, 29 (01): : 15 - 17
  • [4] FOCAL SPOT SIZE MEASUREMENTS FOR MICROFOCUS X-RAY SETS
    MADSEN, JU
    NDT INTERNATIONAL, 1989, 22 (05): : 292 - 296
  • [5] The influence of aperture on the imaging quality of microfocus x-ray source
    Dong, Zengya
    Shi, Lina
    Niu, Geng
    Wang, Wenbo
    Liu, Junbiao
    Han, Li
    X-RAY SPECTROMETRY, 2024, 53 (04) : 242 - 248
  • [6] DETERMINATION OF FOCAL-SPOT CHARACTERISTICS OF MICROFOCUS X-RAY TUBES
    SAKUMA, S
    AYAKAWA, Y
    OKUMURA, Y
    MAEKOSHI, H
    INVESTIGATIVE RADIOLOGY, 1969, 4 (05) : 335 - +
  • [7] Measurement of Focal Spot for Microfocus X-ray Machine by Knife Edge Tool
    Sun C.-M.
    Sun, Chao-Ming, 1600, Atomic Energy Press (51): : 1488 - 1493
  • [8] Time-coded aperture for x-ray imaging
    Ching, Daniel
    Aslan, Selin
    Nikitin, Viktor
    Gursoy, Doga
    OPTICS LETTERS, 2019, 44 (11) : 2803 - 2806
  • [9] CODED APERTURE IMAGING IN X-RAY AND GAMMA-RAY ASTRONOMY
    CAROLI, E
    STEPHEN, JB
    DICOCCO, G
    NATALUCCI, L
    SPIZZICHINO, A
    SPACE SCIENCE REVIEWS, 1987, 45 (3-4) : 349 - 403
  • [10] Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector
    Russo, Paolo
    Mettivier, Giovanni