Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants

被引:19
|
作者
Patzer, Theresa Sophie [1 ]
Kunz, Andreas Steven [1 ]
Huflage, Henner [1 ]
Gruschwitz, Philipp [1 ]
Pannenbecker, Pauline [1 ]
Afat, Saif [2 ]
Herrmann, Judith [2 ]
Petritsch, Bernhard [1 ]
Bley, Thorsten Alexander [1 ]
Grunz, Jan-Peter [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacherstr 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
关键词
Artifact; Tomography; X-ray computed; Dental implants; DUAL-ENERGY CT; RECONSTRUCTION; QUALITY; HEAD;
D O I
10.1007/s00330-023-09790-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives While established for energy-integrating detector computed tomography (CT), the effect of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR) in photon-counting detector (PCD) CT lacks thorough investigation. This study evaluates VMI, iMAR, and combinations thereof in PCD-CT of patients with dental implants. Material and methods In 50 patients (25 women; mean age 62.0 9.9 years), polychromatic 120 kVp imaging (T3D), VMI, T3D(iMAR), and VMIiMAR were compared. VMIs were reconstructed at 40, 70, 110, 150, and 190 keV. Artifact reduction was assessed by attenuation and noise measurements in the most hyper- and hypodense artifacts, as well as in artifact-impaired soft tissue of the mouth floor. Three readers subjectively evaluated artifact extent and soft tissue interpretability. Furthermore, new artifacts through overcorrection were assessed. Results iMAR reduced hyper-/hypodense artifacts (T3D 1305.0/-1418.4 versus T3D(iMAR) 103.2/-46.9 HU), soft tissue impairment (106.7 versus 39.7 HU), and image noise (16.9 versus 5.2 HU) compared to non-iMAR datasets (p <= 0.001). VMIiMAR >= 110 keV subjectively enhanced artifact reduction over T3D(iMAR) (p <= 0.023). Without iMAR, VMI displayed no measurable artifact reduction (p >= 0.186) and facilitated no significant denoising over T3D (p >= 0.366). However, VMI >= 110 keV reduced soft tissue impairment (p <= 0.009). VMIiMAR >= 110 keV resulted in less overcorrection than T3D(iMAR) (p <= 0.001). Inter-reader reliability was moderate/good for hyperdense (0.707), hypodense (0.802), and soft tissue artifacts (0.804). Conclusion While VMI alone holds minimal metal artifact reduction potential, iMAR post-processing enabled substantial reduction of hyperdense and hypodense artifacts. The combination of VMI >= 110 keV and iMAR resulted in the least extensive metal artifacts. Clinical relevanceCombining iMAR with VMI represents a potent tool for maxillofacial PCD-CT with dental implants achieving substantial artifact reduction and high image quality.
引用
收藏
页码:7818 / 7829
页数:12
相关论文
共 50 条
  • [1] Photon-counting detector computed tomography for metal artifact reduction: a comparative study of different artifact reduction techniques in patients with orthopedic implants
    Pallasch, Fabian Bernhard
    Rau, Alexander
    Reisert, Marco
    Rau, Stephan
    Diallo, Thierno
    Stein, Thomas
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    RADIOLOGIA MEDICA, 2024, 129 (06): : 890 - 900
  • [2] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [3] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13
  • [4] Reduction of Metal Artifact in Single Photon-Counting Computed Tomography by Spectral-Driven Iterative Reconstruction Technique
    Nasirudin, Radin A.
    Mei, Kai
    Panchev, Petar
    Fehringer, Andreas
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    PLOS ONE, 2015, 10 (05):
  • [5] Impact of different metal artifact reduction techniques in photon-counting computed tomography head and neck scans in patients with dental hardware
    Pallasch, Fabian Bernhard
    Rau, Alexander
    Reisert, Marco
    Rau, Stephan
    Diallo, Thierno
    Stein, Thomas
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    EUROPEAN RADIOLOGY, 2024, 34 (06) : 3742 - 3749
  • [6] Artifact Reduction From Dental Material in Photon-Counting Detector Computed Tomography Data Sets Based on High-keV Monoenergetic Imaging and Iterative Metal Artifact Reduction Reconstructions-Can We Combine the Best of Two Worlds?
    Risch, Franka
    Decker, Josua A.
    Popp, Daniel
    Sinzinger, Andrea
    Braun, Franziska
    Bette, Stefanie
    Jehs, Bertram
    Haerting, Mark
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 691 - 696
  • [7] Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma
    Alagic, Zlatan
    Duran, Carlos Valls
    Suzuki, Chikako
    Halldorsson, Kolbeinn
    Svensson-Marcial, Anders
    Saeter, Rebecca
    Koskinen, Seppo K.
    ABDOMINAL RADIOLOGY, 2025, 50 (04) : 1720 - 1730
  • [8] Metal Artifact Reduction Computed Tomography of Arthroplasty Implants Effects of Combined Modeled Iterative Reconstruction and Dual-Energy Virtual Monoenergetic Extrapolation at Higher Photon Energies
    Khodarahmi, Iman
    Haroun, Reham R.
    Lee, Moses
    Fung, George S. K.
    Fuld, Matthew K.
    Schon, Lew C.
    Fishman, Elliot K.
    Fritz, Jan
    INVESTIGATIVE RADIOLOGY, 2018, 53 (12) : 728 - 735
  • [9] Metal artifact reduction and tumor detection using photon-counting multi-energy computed tomography
    Lee, Chang-Lae
    Park, Junyoung
    Nam, Sangnam
    Choi, Jiyoung
    Choi, Yuna
    Lee, Sangmin
    Lee, Kyoung-Yong
    Cho, Minkook
    PLOS ONE, 2021, 16 (03):
  • [10] Assessment of quantitative information for radiation therapy at a first-generation clinical photon-counting computed tomography scanner
    Hu, Guyue
    Niepel, Katharina
    Risch, Franka
    Kurz, Christopher
    Wuerl, Matthias
    Kroencke, Thomas
    Schwarz, Florian
    Parodi, Katia
    Landry, Guillaume
    FRONTIERS IN ONCOLOGY, 2022, 12