Combined drug screening and confirmation by liquid chromatography time-of-flight mass spectrometry with reverse database search

被引:0
作者
Ana de Castro
Merja Gergov
Pekka Östman
Ilkka Ojanperä
Anna Pelander
机构
[1] Institute of Forensic Sciences,Research Department
[2] Faculty of Medicine,Hjelt Institute, Department of Forensic Medicine
[3] Cienytech,undefined
[4] University of Helsinki,undefined
来源
Analytical and Bioanalytical Chemistry | 2012年 / 403卷
关键词
LC-TOFMS; Drug screening; Confirmation; Identification;
D O I
暂无
中图分类号
学科分类号
摘要
A method based on in-source collision-induced dissociation (ISCID) liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) and reverse target database search was developed and evaluated for drug screening and confirmation in analytical toxicology context. An established LC-TOFMS screening method, in which identification relies solely on protonated molecule accurate mass measurement, isotopic pattern fit, and retention time (RT), was completed to include 1–3 qualifier ions for each analyte in the database. The qualifier ions for 431 compounds were selected from the experimental ISCID spectra, and their molecular formulae were assigned by applying SmartFormula3D and MSFragmenter software. Three qualifier ions were assigned for 64.5%, two or three for 81.4%, one for 14.8%, and none for 3.7% of the compounds studied. Comparison between ISCID LC-TOFMS and LC-TOFMS with 25 authentic autopsy urine samples showed an improved confidence level with the ISCID method, as isomeric interferences were excluded in most cases. However, some false negative (FN) results were obtained at low concentration levels close to the reporting criteria. The cut-off concentration of the ISCID method was 10–100 ng/mL with 80% of the 49 representative compounds tested, and the level was approximately two times higher than that obtained by LC ion trap MS. The presented method enables simultaneous screening and confirmation whenever at least one qualifier ion is available, as applying an accurate mass precursor ion and one product ion surpasses the standard of four identification points that is required by the current EU protocol.
引用
收藏
页码:1265 / 1278
页数:13
相关论文
共 119 条
  • [1] Haskins NJ(2001)Faster compound analysis by mass spectrometry—the ToF revolution J Pharm Biomed Anal 25 767-773
  • [2] Eckers C(1997)The use of liquid chromatography combined with a quadrupole time-of-flight analyser for the identification of trace impurities in drug substance Rapid Commun Mass Spectrom 11 1916-1922
  • [3] Haskins N(1999)Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer J Am Soc Mass Spectrom 10 1305-1314
  • [4] Langridge J(2000)Evaluation of automated single mass spectrometry to tandem mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole time-of-flight mass spectrometer Rapid Commun Mass Spectrom 14 1787-1792
  • [5] Hopfgartner G(2001)Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas Rapid Commun Mass Spectrom 15 521-526
  • [6] Chernushevich IV(2000)Atmospheric pressure ionization time-of-flight mass spectrometry coupled with fast liquid chromatography for quantitation and accurate mass measurement of five pharmaceutical drugs in human plasma J Mass Spectrom 35 423-431
  • [7] Covey T(2001)Screening for anabolic steroids and related compounds in illegal cocktails by liquid chromatography/time-of-flight mass spectrometry and liquid chromatography/quadrupole time-of-flight tandem mass spectrometry with accurate mass measurement Rapid Commun Mass Spectrom 15 1577-1585
  • [8] Plomley JB(2001)Exact mass measurements for confirmation of pesticides and herbicides determined by liquid chromatography/time-of-flight mass spectrometry Anal Chem 73 5436-5440
  • [9] Bonner R(2002)Accurate mass analysis of ethanesulfonic acid degradates of acetochlor and alachlor using high-performance liquid chromatography and time-of-flight mass spectrometry J Chromatogr A 957 3-9
  • [10] Decaestecker TN(2010)Perspectives of liquid chromatography coupled to low- and high-resolution mass spectrometry for screening, identification, and quantification of drugs in clinical and forensic toxicology Ther Drug Monit 2010 324-327