Electrochemical determination of NADH using a glassy carbon electrode modified with Fe3O4 nanoparticles and poly-2,6-pyridinedicarboxylic acid, and its application to the determination of antioxidant capacity

被引:0
作者
Lin Cui
Shiyun Ai
Kun Shang
Xiaomeng Meng
Chengcheng Wang
机构
[1] Shandong Agricultural University,College of Chemistry and Material Science
[2] Nanjing University,College of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2011年 / 174卷
关键词
APTS-Fe; O; nanoparticles; Poly-2,6-pyridinedicarboxylic acid; NADH; Determination; Electrochemistry;
D O I
暂无
中图分类号
学科分类号
摘要
We have prepared a glassy carbon electrode modified with poly-2,6-pyridinedicarboxylic acid and with magnetic Fe3O4 nanoparticles. This modification enhances the effective surface area and the electrocatalytic oxidation of nicotinamide adenine dinucleotide (NADH) in addition to providing positively charged groups for electrostatic assembly of the phosphate group of NADH. The modified electrode responds linearly to NADH in the range from 5 × 10−8 to 2.5 × 10−5 M and gives a lower detection limit of 1 × 10−8 M. It displays satisfactory selectivity and reproducibility. The sensor was applied to rapid screening of plant extracts for their antioxidant properties.
引用
收藏
页码:31 / 39
页数:8
相关论文
共 185 条
[1]  
Katakis I(1997)Catalytic electrooxidation of NADH for dehydrogenase amperometric biosensors mikrochim Acta 126 11-32
[2]  
Domínguez E(1996)Electrocatalytic oxidation of NADH at glassy carbon electrodes modified with transition metal complexes containing 1, 10-phenanthroline-5, 6-dione ligands Anal Chem 68 3688-3696
[3]  
Wu Q(1999)Electrocatalytic oxidation of NADH at graphite electrodes modified with osmium phenanthrolinedione J Electroanal Chem 464 208-214
[4]  
Maskus M(1994)Amperometric NADH determination via both direct and mediated electron transfer by NADH oxidase from Thermus aquaticus YT-1 Anal Chim Acta 295 47-57
[5]  
Pariente F(2010)Electrochemical determination of NADH and ethanol based on ionic liquid-functionalized graphene Biosens Bioelectron 25 1504-1508
[6]  
Tobalina F(2003)The effect of calcium ions on the electrocatalytic oxidation of NADH by poly (aniline)-poly (vinylsulfonate) and poly (aniline)-poly (styrenesulfonate) modified electrodes Phys Chem Chem Phys 5 588-593
[7]  
Fernández V(2000)Poly (aniline)-poly (acrylate) composite films as modified electrodes for the oxidation of NADH Phys Chem Chem Phys 2 2599-2606
[8]  
Lorenzo E(1996)Electrocatalytic detection of nicotinamide coenzymes by poly (o-aminophenol)-and poly (o-phenylenediamine)-modified carbon paste electrodes Anal Chim Acta 325 33-42
[9]  
Abruña H(1981)Catalytic oxidation of NADH by surface-modified graphite electrodes J Electroanal Chem 130 199-207
[10]  
Popescu IC(1981)Development of new analytical systems based on biocatalysers Anal Lett 14 377-73