Measurement Class Phasor Measurement Unit Compliance for Electrical Grid Monitoring

被引:0
作者
Mohan Thakre
Akbar Ahmad
Kishor Bhadane
机构
[1] K. K. Wagh Institute of Engineering Education and Research,Electrical Engineering Department
[2] School of Engineering and Technology,Electrical Engineering Department
[3] Amrutvahini College of Engineering,Electrical Engineering Department
来源
MAPAN | 2022年 / 37卷
关键词
Synchrophasor; IEC/IEEE 60,255-118.1:2018; Steady-state; Dynamic compliance; Total vector error;
D O I
暂无
中图分类号
学科分类号
摘要
This article offers synchrophasor transient and steady compliance with IEC/IEEE 60,255-118-1:2018 standard. This power system standard is mainly designed for the synchronized phasor measurement and specifies the synchronized voltage and current phasors, frequency and derivative requirements, time tag, and synchronization of all measurements. The Synchrophasor testbed includes three-phase high-precision power and current signal voltage, system time unit, GPS receiver, server PC, electricity standards, PMUCAL and test-based PMU software. Three-Phase Measurement Units (PMUs) from different machines have been tested individually to confirm compliance with the state-of-the-art international standard, which is essentially a dual logo standard. Such measured information is being used to control the power grid by smart communication utility. The test results of synchrophasor have been analyzed and discussed.
引用
收藏
页码:125 / 135
页数:10
相关论文
共 33 条
  • [1] Bose A(2010)Smart transmission grid applications and their supporting infrastructure IEEE Trans. Smart Grid 1 1119-66
  • [2] Razo-Hernandez JR(2020)A new phasor estimator for pmu applications: P class and M class J. Mod. Power Syst. Clean Energy 8 55-17
  • [3] Mejia-Barron A(2013)A new algorithm to compute fault synchrophasor from transient state synchrophasor in PDC IEEE Power Energy Soc. Gen. Meet. 10 1-336
  • [4] Granados-Lieberman D(2018)Adaptive digital distance relay for SSSC based double-circuit transmission line using phasor measurement unit Int. Trans. on Elect. Energ. Syst. 77 327-18
  • [5] Valtierra-Rodriguez M(2016)An adaptive approach for three zone operation of digital distance relay with Static Var compensator using PMU Electrical Power Energy Syst. 28 1-3961
  • [6] Gomez-Aguilar JF(2018)Effect of SSSC based SSR controller on the performance of distance relay and adaptive approach using synchronized measurement Int. Trans. on Elect. Energ. Syst. 14 3953-973
  • [7] Das S(2020)A novel frequency estimation method based on complex bandpass filters for P-class PMUs with short reporting latency IEEE Trans. on Power Delivery 62 963-309
  • [8] Sidhu T(2020)Second-order matrix pencil-based phasor measurement algorithm for P-class PMUs IET Generation, Transmission & Distribution 7 300-1459
  • [9] Koteswara Raju D(2013)Synchrophasor estimators accuracy: A comparative analysis IEEE Trans. Instrum. Meas. 28 1447-1669
  • [10] Singh A(2016)Power system real-time monitoring by using PMU-based robust state estimation method IEEE Trans. on Smart Grid 3 1660-330