Personalised modified osteotomy using computer-aided design–rapid prototyping to correct thoracic deformities

被引:0
作者
Jin Cheng Yang
Xiang Yang Ma
Jun Lin
Zeng Hui Wu
Kai Zhang
Qing Shui Yin
机构
[1] Liu Hua Qiao Hospital,Department of Orthopedics
[2] Southern Medical University,Department of Cell Biology, School of Basic Medical Science
来源
International Orthopaedics | 2011年 / 35卷
关键词
Pedicle Screw; Spinal Deformity; Thoracic Kyphosis; Wedge Osteotomy; Open Wedge Osteotomy;
D O I
暂无
中图分类号
学科分类号
摘要
The correction of severe thoracic deformities is challenging. However, the usual imaging modalities are not sufficient for performing the surgery. Our objective was to describe the procedure and results of posterior modified wedge osteotomy aided by the techniques of computer-aided design–rapid prototyping (CAD-RP) to correct thoracic deformities. Twenty-one patients with thoracic deformities (eight males; 13 females) formed the study group. All patients underwent computed tomography (CT) scanning and CAD-RP, and a model of thoracic deformities and navigation templates of pedicles were created for each patient and used to analyse the spinal deformities and serve as anatomical reference. Aided by these models, personalised modified wedge osteotomy combining the eggshell technique and posterior vertebral column resection was performed. Using CAD-RP improved the safety and accuracy of surgery and screw placement in the 21 patients in whom 41 vertebrae were removed and 216 pedicle screws were placed. The average operation time was 260 (200–420) min, with an average blood loss of 1,900 ml (range 800–3560 ml). The percentage of deformity correction was 56.3% (from 72.1° to 31.5°) in the coronal plane and 60.4% (from 81.6° to 32.3°) in the sagittal plane. No patient had serious complications or implant failure. Personalised single-stage posterior modified wedge osteotomy is an effective procedure for treating thoracic deformities. Using CAD-RP and the RP models have significant benefits for personalised surgical treatment of complex thoracic deformities.
引用
收藏
页码:1827 / 1832
页数:5
相关论文
共 70 条
[1]  
Guarino J(2007)Rapid prototyping technology for surgeries of the pediatric spine and pelvis: benefits analysis J Pediatr Orthop 27 955-960
[2]  
Tennyson S(2009)CAD/CAM and rapid prototyped scaffold construction for bone regenerative medicine and surgical transfer of virtual planning: A pilot study Comput Med Imaging Graph 33 58-62
[3]  
McCain G(2007)The use of physical biomodelling in complex spinal surgery Eur Spine J 16 1507-1518
[4]  
Cioccaa L(1998)Rapid prototyping for orthopaedic surgery Proc Inst Mech Eng H J Eng Med 212 383-393
[5]  
Crescenziob FD(2002)Feasibility study of patient-specific surgical templates for the fixation of pedicle screws Stud Health Technol Inform 88 419-422
[6]  
Scotti MFR(2007)Rapid prototype patient-specific drill template for cervical pedicle screw placement Comput Aided Surg 12 303-308
[7]  
Izatt MT(2005)Personalised imagebased templates for intra-operative guidance Proc Inst Mech Eng 219 111-118
[8]  
Thorpe PLPJ(2001)Measurement accuracy in congenital scoliosis J Bone Joint Surg Am 83 42-45
[9]  
Thompson RG(2010)Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study Eur Spine J 19 797-802
[10]  
Potamianos P(2005)Biomodeling as an aid to spinal instrumentation Spine 30 841-2845