Blood glucose monitoring in human subjects using optical coherence tomography

被引:11
作者
Jitendra Solanki
Pratima Sen
Joseph Thomas Andrews
Kamal Kishore Thareja
机构
[1] Department of Applied Physics, Shri G S Institute of Technology and Science
[2] Laser Bhawan, School of Physics, Devi Ahilya University, Indore 452 007, Khandwa Road
[3] KK Pathology Lab., Chanakya Complex, Malwa Mill Chourah
关键词
Blood glucose; Diabetes; Diffusion; Light scattering; Optical coherence tomography;
D O I
10.1007/s12596-012-0067-z
中图分类号
学科分类号
摘要
The utility of optical coherence tomography signal amplitude for the measurement of glucose concentration has been analyzed in tissue phantom and in blood samples from human subjects. The diffusion equation based calculations as well as in-vivo OCT signal measurements confirm a cyclic correlation of signal intensity with glucose concentration and scatterer size. © Optical Society of India 2012.
引用
收藏
页码:127 / 133
页数:6
相关论文
共 22 条
[1]  
Bazaev N.A., Selishchev S.V., Noninvasive methods for blood glucose measurement, Biomed. Eng., 41, pp. 40-48, (2007)
[2]  
Amaral C.F., Brischwein M., Wolf B., Multiparameter techniques for noninvasive measurement of blood glucose, Sensors and Actuators B, 140, pp. 12-16, (2009)
[3]  
Rabinovitch B., March W.F., Adams R.L., Noninvasive glucose monitoring of the aqueous humor of the eye, part 1, measurement of very small optical rotations, Diabetes Care, 5, pp. 254-258, (1982)
[4]  
Cote G.L., Fox M.D., Northrop R.B., Noninvasive optical polarimetric glucose sensing using a true phase measurement technique, IEEE Trans. Biomed. Eng., 39, pp. 752-756, (1992)
[5]  
Larin K.V., Motamedi M., Eledrisi M.S., Esenaliev R.O., Noninvasive blood glucose monitoring with optical coherence tomography, Diabetes Care, 25, pp. 2263-2267, (2002)
[6]  
Poddar R., Sharma S.R., Andrews J.T., Sen P., Study of correlation between glucose concentration and reduced scattering coefficients in turbid media using optical coherence tomography, Curr. Sci., 95, (2008)
[7]  
Pickup J.C., Hussain F., Evans N.D., Rolinski O.J., Birch D.J.S., Fluorescence-based glucose sensors, Biosens. Bioelectron., 20, pp. 2555-2565, (2005)
[8]  
McNichols J.R., Cote L.G., Optical glucose sensing in biological fluids: An overview, J. Biomed. Opt., 5, pp. 5-16, (2000)
[9]  
Malin S.F., Ruchiti T.L., Blank T.B., Thennadil S.U., Monfre S.L., Noninvasive prediction of glucose by near infrared diffuse reflectance spectroscopy, Clini. Chem., 45, pp. 1651-1658, (1999)
[10]  
Ashok V., Nirmalkumar A., Jeyashanthi N., A novel method for blood glucose measurement by noninvasive technique using laser, International Journal of Biological and Life Sciences, 6, 3, (2010)