Rhodium Nanoparticle-mesoporous Silicon Nanowire Nanohybrids for Hydrogen Peroxide Detection with High Selectivity

被引:0
作者
Zhiqian Song
Hucheng Chang
Weiqin Zhu
Chenlong Xu
Xinjian Feng
机构
[1] Suzhou Institute of Nano-Tech and Nano-Bionics,Nanobionics Division & Key Laboratory of Nano
[2] Chinese Academy of Sciences,Bio Interface
来源
Scientific Reports | / 5卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Developing nanostructured electrocatalysts, with low overpotential, high selectivity and activity has fundamental and technical importance in many fields. We report here rhodium nanoparticle and mesoporous silicon nanowire (RhNP@mSiNW) hybrids for hydrogen peroxide (H2O2) detection with high electrocatalytic activity and selectivity. By employing electrodes that loaded with RhNP@mSiNW nanohybrids, interference caused from both many electroactive substances and dissolved oxygen were eliminated by electrochemical assaying at an optimal potential of +75 mV. Furthermore, the electrodes exhibited a high detection sensitivity of 0.53 μA/mM and fast response (< 5 s). This high-performance nanohybrid electrocatalyst has great potential for future practical application in various oxidase-base biosensors.
引用
收藏
相关论文
共 79 条
[11]  
Rivas GA(2001)A novel glucose biosensor based on the nanoscaled cobalt phthalocyanine-glucose oxidase biocomposite Electroanalysis. 13 1179-1184
[12]  
Miscoria SA(2011)Tetracarboxylic acid cobalt phthalocyanine SAM on gold: potential applications as amperometric sensor for H Biomaterials. 32 4885-4895
[13]  
Barrera GD(2009)O Anal. Chem. 81 5603-5613
[14]  
Rivas GA(2009) and fabrication of glucose biosensor Anal. Chem. 81 2378-2382
[15]  
Miscoria SA(2003)Highly selective first generation glucose biosensor based on carbon paste containing copper and glucose oxidase J. Am. Chem. Soc. 125 2408-2409
[16]  
Barrera GD(2003)The intrinsic redox reactions of polyamic acid derivatives and their application in hydrogen peroxide sensor Anal. Chem. 75 2075-2079
[17]  
Rivas GA(2008)Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide Biosens. Bioelectron. 23 771-779
[18]  
Chang H(1994)Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene Anal. Chem. 66 1007-1011
[19]  
Wang K(1994)Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors Anal. Chem. 66 3600-3603
[20]  
Xu J-J(1979)Carbon nanotube/teflon composite electrochemical sensors and biosensors Anal. Chem. 51 444-449