Low-dose spiral CT: applicability to paediatric chest imaging

被引:0
|
作者
P. Rogalla
Brigitte Stöver
Ianina Scheer
Ralf Juran
Gerhard Gaedicke
Bernd Hamm
机构
[1] Department of Diagnostic and Interventional Radiology,
[2] Charité Hospital,undefined
[3] Humboldt-Universität zu Berlin,undefined
[4] Schumannstrasse 20/21,undefined
[5] D-10 117 Berlin,undefined
[6] Germany,undefined
[7] Department of Pediatrics,undefined
[8] Charité Hospital,undefined
[9] Humboldt-Universität zu Berlin,undefined
[10] Germany,undefined
来源
Pediatric Radiology | 1999年 / 29卷
关键词
Diagnostic Image Quality; Thermoluminescent Dosimeter; Paediatric Chest; Adequate Image Quality; Tube Energy;
D O I
暂无
中图分类号
学科分类号
摘要
Background. Spiral CT of the chest is an imaging technique with unequivocal indications and proven higher sensitivity and specificity than conventional chest X-rays. However, particularly in children, attempts should be made to reduce radiation exposure to a minimum. Objective. To evaluate whether a low-dose technique in spiral CT scanning results in adequate diagnostic information. Materials and methods. In a prospective study, 27 children (range 3 weeks to 14 years, mean 7 years) underwent a low-dose CT examination of the chest for various indications. The tube energy was 12.5 mAs (n = 5), 25 mAs (n = 17), 50 mAs (n = 3), or 75 mAs (n = 2) per slice. Two radiologists evaluated, in consensus, the CT scans with respect to their diagnostic value and comparison was made with 20 standard-dose chest CT examinations of adults (175 mAs per slice, mean age 56 years) with respect to technical image quality (noise and artefacts). In a second part of the study, dose measurements were carried out by means of exposing thermoluminescent dosimeters attached to a water/air phantom simulating a child's chest. Results. All low-dose CT scans were of diagnostic image quality and no additional studies were necessary. The average image noise was significantly higher than in standard-dose CT examinations (SD 39.5 compared with 12.5 for unenhanced soft tissue, P < 0.01), but did not hinder accurate diagnosis. Artefacts were exclusively due to patient motion. Radiation exposure per slice was approx. 4 mGy at 25 mAs and 34 mGy at 250 mAs, regardless of slice thickness. Conclusions. For all indications in paediatric CT scanning of the chest, low-dose technique provides adequate image quality without loss of diagnostic information. The radiation exposure is approximately 5–20 % of a standard-dose CT.
引用
收藏
页码:565 / 569
页数:4
相关论文
共 50 条
  • [1] Low-dose spiral CT:: applicability to paediatric chest imaging
    Rogalla, P
    Stöver, B
    Scheer, I
    Juran, R
    Gaedicke, G
    Hamm, B
    PEDIATRIC RADIOLOGY, 1999, 29 (08) : 565 - 569
  • [2] A prospective evaluation of low-dose spiral chest CT in children
    Rigsby, CK
    Benya, EC
    Saker, MC
    Lin, PP
    Shore, RM
    RADIOLOGY, 2001, 221 : 574 - 574
  • [3] EKG-gated Low-dose Chest CT Imaging
    Hsieh, Jiang
    Londt, John
    Dutta, Sandeep
    Okerlund, Darin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1666 - 1669
  • [4] Low-dose spiral chest CT screening of women for common causes of death
    Swensen, SJ
    Hartman, TE
    Brandt, KR
    Sykes, AG
    Quam, JP
    Zink, FE
    RADIOLOGY, 1998, 209P : 222 - 222
  • [5] Low-dose spiral-CT
    Diederichs, CG
    Bruhn, H
    Funke, M
    Grabbe, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (03): : 183 - 188
  • [6] Low-dose spiral CT screening
    Parles, K
    CHEST, 2001, 120 (03) : 1042 - 1043
  • [7] Ultra low-dose helical CT of the chest
    Nitta, N
    Takahashi, M
    Murata, K
    Morita, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 383 - 385
  • [8] Low-dose spiral CT: Application to three-dimensional imaging of central airways
    Choi, Y
    McAdams, HP
    Jeon, SC
    Park, C
    Lee, S
    Hahm, C
    RADIOLOGY, 2000, 217 : 385 - 385
  • [9] CLINICAL-APPLICATIONS OF LOW-DOSE CHEST CT
    BERKMAN, YM
    ROMNEY, BM
    AUSTIN, JH
    RADIOLOGY, 1992, 185 : 266 - 267
  • [10] Low-dose chest CT and the impact on nodule visibility
    Tugwell-Allsup, J.