Evaluation of Tungsten Coil Atomic Emission Spectrometry for the Direct Determination of Al in Tea Infusions and Iced Tea

被引:0
|
作者
Luana N. Santos
Mário H. Gonzalez
Monise F. Moura
George L. Donati
Joaquim A. Nóbrega
机构
[1] Santa Cruz State University at Soane Nazaré de Andrade,Department of Exacts and Technological Ssciences
[2] Santa Cruz State University,Department of Chemistry and Environmental Sciences, Institute of Biosciences, Letters, and Exact Sciences
[3] Federal University of São Carlos,Group of Applied Instrumental Analysis, Department of Chemistry
[4] Wake Forest University,Department of Chemistry
来源
Food Analytical Methods | 2016年 / 9卷
关键词
Tungsten coil; Atomic emission; Aluminum; Tea;
D O I
暂无
中图分类号
学科分类号
摘要
This work describes the determination of aluminum in tea infusions and iced tea by tungsten coil atomic emission spectrometry (WCAES). The instrumentation is simple, inexpensive, and potentially portable. It uses a tungsten filament extracted from 150 W, 15 V commercially available slide projector light bulbs as electrothermal atomizer. A simple power supply that provides a constant potential is used to heat the coil. Tea infusions were directly analyzed by application of an optimized heating program. In order to avoid matrix interferences, the iced tea samples were diluted with an oxidizing mixture composed of hydrogen peroxide and nitric acid and also analyzed by a tailored heating program. Aluminum was quantified in all samples, and the results were in agreement with those obtained by inductively coupled plasma optical emission spectrometry at a 95 % confidence level. The limit of detection and the relative standard deviation for a solution containing 2.5 mg L−1 Al (n = 10) were determined, and the values were 0.09 mg L−1 and 5.1 %, respectively.
引用
收藏
页码:624 / 629
页数:5
相关论文
共 50 条
  • [31] Sequential Determination of Cd, Cu and Pb in Tea Leaves by Slurry Introduction to Thermospray Flame Furnace Atomic Absorption Spectrometry
    Miranda, Kelber
    Pereira-Filho, Edenir R.
    FOOD ANALYTICAL METHODS, 2013, 6 (06) : 1607 - 1610
  • [32] Evaluation of a modified spectrometer for electrothermal atomic absorption spectrometry with tungsten coils. Determination of chromium
    Knochen, M
    Saritsky, E
    Dol, I
    QUIMICA ANALITICA, 1996, 15 (02): : 184 - 190
  • [33] Determination of F, Na, Mg, Al and P in Indian tea powders by a proton induced γ-ray emission technique
    Sunitha, Y.
    Sarkar, A.
    Kumar, Sanjiv
    ANALYTICAL METHODS, 2016, 8 (39) : 7116 - 7123
  • [34] DETERMINATION OF TRACE-METALS IN TEA USING BOTH MICROWAVE DIGESTION AT ATMOSPHERIC-PRESSURE AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    LAMBLE, K
    HILL, SJ
    ANALYST, 1995, 120 (02) : 413 - 417
  • [35] Evaluation of a radio frequency-powered selenium hollow cathode lamp for tungsten-coil atomic absorption spectrometry
    Hou, XD
    Yang, Z
    Jones, BT
    APPLIED SPECTROSCOPY, 2002, 56 (05) : 673 - 676
  • [36] Determination of eight pesticide residues in tea by liquid chromatography-tandem mass spectrometry and its uncertainty evaluation
    Hu Beizhen
    Cai Haijiang
    Song Weihua
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (09) : 889 - 895
  • [37] Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry
    Soylak, Mustafa
    Tuzen, Mustafa
    Souza, Anderson Santos
    Andrade Korn, Maria Das Gracas
    Costa Ferreira, Sergio Luis
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (02) : 264 - 268
  • [38] Determination of Trace Silver in Water Samples by Solid Phase Extraction Portable Tungsten-Coil Electrothermal Atomic Absorption Spectrometry
    Fan Guang-yu
    Jiang Xiao-ming
    Zheng Cheng-bin
    Hou Xian-deng
    Xu Kai-lai
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (07) : 1946 - 1949
  • [39] Flow injection hydride generation for on-atomizer trapping: Highly sensitive determination of cadmium by tungsten coil atomic absorption spectrometry
    Chen, Piaopiao
    Deng, Yujia
    Guo, Kuncheng
    Jiang, Xiaoming
    Zheng, Chengbin
    Hou, Xiandeng
    MICROCHEMICAL JOURNAL, 2014, 112 : 7 - 12
  • [40] Hollow fiber supported liquid membrane extraction for ultrasensitive determination of trace lead by portable tungsten coil electrothermal atomic absorption spectrometry
    Zeng, Chujie
    Wen, Xiaodong
    Tan, Zhiqiang
    Cai, Pingyang
    Hou, Xiandeng
    MICROCHEMICAL JOURNAL, 2010, 96 (02) : 238 - 242