Voltammetric determination of phentolamine mesylate in pharmaceutical formulations at poly (4-aminobenzene sulfonic acid)-modified glassy carbon electrode

被引:0
作者
Sen Fan
Lei Ji
Guoliang Mao
Xin Sui
Huan Wang
Yuanhai Zhu
Hua Song
机构
[1] Northeast Petroleum University,College of Petroleum Engineering
[2] Northeast Petroleum University,College of Chemistry and Chemical Engineering
来源
Chemical Papers | 2020年 / 74卷
关键词
Phentolamine; Electropolymerization; 4-Aminobenzene sulfonic acid; Modified glassy carbon electrode;
D O I
暂无
中图分类号
学科分类号
摘要
A poly (4-aminobenzene sulfonic acid)-modified glassy carbon electrode (p-ABSA/GCE) was fabricated by electropolymerization. It was found that phentolamine mesylate, an effective and important cardiovascular dilatation drug with low redox activity at the glassy carbon electrode (GCE) can produce a sensitive well-defined anodic peak current at p-ABSA/GCE. Investigation indicated that the oxidation of phentolamine at p-ABSA/GCE was one electron/one proton transfer process which was controlled by adsorption. In optimal conditions, the anodic peak current was linear to the concentrations of phentolamine over the range of 5.0 × 10–7–1.0 × 10–5 M with a detection limit of 2.0 × 10–7 M. The modified electrode showed good stability and reproducibility. The electroanalytical method proposed was successfully applied to the determination of phentolamine mesylate in pharmaceutical formulations.
引用
收藏
页码:4411 / 4417
页数:6
相关论文
共 51 条
  • [1] Bros FD(1978)Determination of phentolamine in blood and urine by high-performance liquid-chromatography Anal Chem 50 521-525
  • [2] Wolshin EM(1981)Determination of the major metabolite of phentolamine in human plasma and urine by high-performance liquid chromatography J Chromatogr B 222 461-466
  • [3] Godbillon J(2005)Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid Sens Actuat B 107 528-534
  • [4] Carnis G(1979)General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems J Electroanal Chem 101 19-28
  • [5] Jin GY(2014)A sensitive voltammetric sensor for salbutamol based on MWNTs composite nano-Au film modified electrode Anal Methods 6 1928-1935
  • [6] Zhang YZ(2014)Electrochemically reduced graphene oxide-based electrochemical sensor for the sensitive determination of ferulic acid in A. sinensis and biological samples Mater Sci Eng C 42 227-233
  • [7] Cheng WX(2002)Simultaneous identification/determination system for phentolamine and sildenafil as adulterants in soft drinks advertising roborant nutrition Forensic Sci Int 130 140-146
  • [8] Laviron E(1983)Permselectivity of films prepared by electrochemical oxidation of phenol and aminoaromatic compounds J Electroanal Chem 158 55-67
  • [9] Li YF(2002)Long-term safety and efficacy of oral phentolamine mesylate (Vasomax) in men with mild to moderate erectile dysfunction Int J Impot Res 14 266-270
  • [10] Ye Z(2013)Effect of surfactants on the voltammetric response and determination of an antihypertensive drug phentolamine at boron doped diamond electrode ECS Trans 50 23-36