Exergetic performance evaluation of solar air heater having V-down perforated baffles on the absorber plate

被引:0
作者
S. Chamoli
N. S. Thakur
机构
[1] National Institute of Technology,Centre for Energy and Environment
来源
Journal of Thermal Analysis and Calorimetry | 2014年 / 117卷
关键词
Perforated baffles; Exergy; Solar air heater; Design plot; Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
Baffles serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Perforated baffles are relatively good heat transfer augmentation features with superior performance over conventional smooth duct solar air heater and as a result find application in some solar air heaters. The exergy method is employed to in determining the roughness parameters, as second law-based exergy analysis is suitable for design of roughened solar air heaters. The exergetic efficiency of V down perforated baffled roughened duct solar air heater is studied analytically, and the results obtained compared with conventional system. Results indicate that high efficiency with optimum V down perforated baffle improves the heat absorption and dissipation potential of a solar air heater. Design plots are prepared to predict the optimum roughness parameter as a function of temperature rise parameter.
引用
收藏
页码:909 / 923
页数:14
相关论文
共 102 条
[1]  
Gupta MK(2008)Exergy performance evaluation and parametric studies of solar air heater Energy. 33 1691-1702
[2]  
Kaushik SC(2012)A review of the turbulence promoters used in solar thermal systems Renew Sustain Energy Rev 16 3154-3175
[3]  
Chamoli S(2000)Thermal performance analysis for solid and perforated blocks attached on a flat surface in duct flow Energy Convers Manag 41 1019-1028
[4]  
Thakur NS(2001)Heat transfer enhancement in a channel flow with perforated rectangular blocks Int J Heat Fluid Flow 22 509-518
[5]  
Saini JS(2002)Numerical simulation of turbulent flow field and heat transfer in a two dimensional channel with periodic slit ribs Int J Heat Mass Transf 45 4493-4505
[6]  
Sara ON(2005)Internal cooling augmentation in rectangular channel using two inclined baffles Int J Heat Fluid Flow 26 223-232
[7]  
Pekdemir T(2005)Experimental study of heat transfer enhancement in an asymmetrically heated rectangular duct with perforated baffles Int Commun Heat Mass Transf 32 275-284
[8]  
Yapici S(2009)Heat transfer and friction in an asymmetrically heated rectangular duct with half and fully perforated baffles at different pitches Int Commun Heat Mass Transf 36 264-268
[9]  
Ersahan H(2000)Investigation for the optimal thermo hydraulic performance of artificially roughened solar air heaters Renew Energy 20 19-36
[10]  
Sara ON(2005)Augmentation of heat transfer coefficient by using 90 Renew Energy 30 2057-2063