Distal locking stem for revision femoral loosening and peri-prosthetic fractures

被引:0
|
作者
Patrice Mertl
Remy Philippot
Philippe Rosset
Henri Migaud
Jacques Tabutin
Denis Van de Velde
机构
[1] CHU Amiens,Orthopaedic Department
[2] CHU Tours,Orthopaedic Department
[3] CHU Saint Etienne,Orthopaedic Department
[4] CHU Lille,Orthpaedic Surgery
[5] CHU Cannes,Orthopaedic Surgery
[6] Clinique du Parc,Orthopaedic Surgery
来源
International Orthopaedics | 2011年 / 35卷
关键词
Femoral Component; Periprosthetic Fracture; Thigh Pain; Bone Reconstruction; Transfemoral Approach;
D O I
暂无
中图分类号
学科分类号
摘要
Revision total hip arthroplasty in the setting of a large proximal femoral deficiency or a peri-prosthetic fracture remains a challenging problem. We describe the development, surgical technique and the use of cementless revision stems with distal inter-locking screws to provide immediate stability of the femoral implant. Results were assessed in a large multicentre French study conducted with the french hip and knee surgery society (SFHG). We retrospectively reviewed 725 revisions using interlocking stems from 14 French orthopaedic departments. Seven different stems were used in this series. In-patient records were retrieved, and in addition to demographic data the indication for revision, the preoperative and postoperative PMA and Harris hip scores were documented. The bone deficiency was classified on the basis of the French National Orthopaedic Meeting (SOFCOT) classification. Intraoperative complications and problems if any were retrieved from operative notes. Clinical status and radiographs at the final follow-up were evaluated, paying special attention to the metaphyseal filling index. Average follow-up was 4.5 years. As for the clinical results, the mean Harris hip score at last follow-up was 81. Therefore, it increased by an average of 31 points. Bone reconstruction was assessed on the cortico-medullary index in the metaphyseal area and at mid-shaft increasing from 36 to 45 and 54 to 63, respectively. Radiologically, 637 implants were stable, and 40 demonstrated subsidence. Forty-eight implants have been revised. We found a significant relation between the metaphyseal filling index, the stability of the stem and the quality of bone reconstruction. Results were analysed with respect to three groups of stems: group 1 was a straight, partially HA-coated implant; group 2 was a curved, fully HA-coated implant; and group 3 was a curved, partially-coated implant. Group 1 showed a significantly higher rate of failure when compared with the others types of implants. Group 2 had better functional results than group 3, which in turn reported better results than group 1. With regard to implant fixation, group 2 had significantly better results. Both groups 2 and 3 induced less thigh pain than group 1. The distal interlocking stem has shown promising results for femoral revisions. The advantages are initial axial and rotational stability and consistent bony in-growth owing to hydroxyapatite coating. Distal locked stems are mainly indicated to treat complex femoral revision with severe bone loss and peri-prosthetic fractures.
引用
收藏
页码:275 / 282
页数:7
相关论文
共 50 条
  • [31] Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures-analysis of results in 13 cases
    Venu, KM
    Koka, R
    Garikipati, R
    Shenava, Y
    Madhu, TS
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 (05): : 395 - 400
  • [32] The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement
    Meek, R. M. D.
    Norwood, T.
    Smith, R.
    Brenkel, I. J.
    Howie, C. R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (01): : 96 - 101
  • [33] Osteosynthesis of distal femoral fractures by locking compression plates
    Ehlinger, Matthieu
    Adam, Philippe
    Abane, Lamine
    Bonnomet, Francois
    Arlettaz, Yvan
    SWISS MEDICAL WEEKLY, 2011, 141 : 19S - 19S
  • [34] 1015 Reducing Waiting Time to Surgery for Patients with Femoral Peri-Prosthetic Fractures (FPP#s): A Quality Improvement Project
    Ayathamattam, J.
    Kumar, V
    Shah, N.
    BRITISH JOURNAL OF SURGERY, 2022, 109 (SUPPL 6)
  • [35] Distal Femur Locking Plate: The Answer to All Distal Femoral Fractures
    Virk, Jagandeep Singh
    Garg, Sudhir Kumar
    Gupta, Parmanand
    Jangira, Vivek
    Singh, Jagdeep
    Rana, Sudhir
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (10) : RC1 - RC5
  • [36] Single-stage revision of peri-prosthetic infection following total elbow replacement
    Gille, J.
    Ince, A.
    Gonzalez, O.
    Katzer, A.
    Loehr, J. F.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (10): : 1341 - 1346
  • [37] A COMPARISON OF TWO COHORTS OF ELDERLY TRAUMA PATIENTS - PERI-PROSTHETIC FRACTURES AND NECK OF FEMUR FRACTURES - ARE THEY SIMILAR?
    Dutton, J.
    Wilkinson, I.
    Babu, S.
    Chougule, S.
    AGE AND AGEING, 2018, 47
  • [38] Management of distal femoral periprosthetic fractures by distal femoral locking plate: A retrospective study.
    Thukral, Rajiv
    Marya, S. K. S.
    Singh, Chandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 199 - 207
  • [39] Revision of the failed distal femoral replacement to allograft prosthetic composite
    Wilkins, RM
    Kelly, CM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (397) : 114 - 118
  • [40] Fixation of Periprosthetic Femoral Shaft Fractures Adjacent to a Well-Fixed Femoral Stem With Reversed Distal Femoral Locking Plate
    Ebraheim, Nabil A.
    Gomez, Carlos
    Ramineni, Satheesh K.
    Liu, Jiayong
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04): : 1152 - 1157