Effective intake for critical submergence in the case of more than one intake

被引:0
作者
Kerem Taştan
Nevzat Yildirim
机构
[1] Gazi University,Faculty of Engineering, Dept. of Civil Engineering
来源
KSCE Journal of Civil Engineering | 2017年 / 21卷
关键词
air-entrainment; critical submergence; intake; submergence; vortex;
D O I
暂无
中图分类号
学科分类号
摘要
The available potential flow solution methods over-estimate the number of effective intake for the prediction of critical submergence in the case of multiple intakes of identical level without partition walls located on the longitudinal line of the canal, because they cannot establish an upper limiting value for the distance between the centers of the intakes. To address this, tests were conducted on dual intakes of identical level located on the longitudinal line of the canal in a cross-flow. In practice, by means of the chart obtained from the experimental results, one can determine the upper limiting value of the distance between the centers of dual intakes beyond which the effect of the intake on the critical submergence of the other intake is negligible. Such an intake is considered a non-effective intake and is disregarded in the prediction of critical submergence. In addition, the effective intake relating to multiple intakes sited in a still-water reservoir is explained.
引用
收藏
页码:1004 / 1008
页数:4
相关论文
共 30 条
[1]  
Ansar M.(2002)Numerical simulations of inviscid three-dimensional flows at single-and dualpump intakes Journal of Hydraulic Research 40 461-470
[2]  
Nakato T.(1957)The prevention of vortices and swirl at intakes Proc. 7th IAHR Congress, Lisbon 1 1-8
[3]  
Constantinescu G.(2002)Effect of circulation on critical submergence of an intake pipe Journal of Hydraulic Research 40 741-752
[4]  
Denny D. F.(2010)Effects of dimensionless parameters on air-entraining vortices Journal of Hydraulic Research 48 57-64
[5]  
Young G. A. J.(1995)Critical submergence for intakes in open channel flow Journal of Hydraulic Engineering 121 900-905
[6]  
Kocaba F.(1998)Critical submergence for intakes in still-water reservoir Journal of Hydraulic Engineering 124 103-104
[7]  
Yıdırım N.(2000)Flow-boundary effects on critical submergence of intake pipe Journal of Hydraulic Engineering 126 288-297
[8]  
Taştan K.(2007)Errata of Flowboundary effects on critical submergence of intake pipe Journal of Hydraulic Engineering 133 461-1062
[9]  
Yıdırım N.(2009)Critical submergence for multiple pipe intakes Journal of Hydraulic Engineering 135 1052-249
[10]  
Yıdırım N.(2009)Critical submergence for dual pipe intakes Journal of Hydraulic Research 47 242-121