Determination of human serum albumin and γ-globulin in a control serum solution by near-infrared spectroscopy and partial least squares regression

被引:0
作者
Koichi Murayama
Keiichi Yamada
Roumiana Tsenkova
Y. Wang
Y. Ozaki
机构
[1] Merchandise Development Laboratory,
[2] Daiken Medical Co.,undefined
[3] Ltd.,undefined
[4] 4–36,undefined
[5] Funaocho-Higashi,undefined
[6] Hamadera,undefined
[7] Sakai 592–8341,undefined
[8] Japan,undefined
[9] Department of Environment Information and Bio-production Engineering,undefined
[10] Faculty of Agriculture,undefined
[11] Kobe University,undefined
[12] Rokkodai,undefined
[13] Nada-ku,undefined
[14] Kobe 657–8501,undefined
[15] Japan,undefined
[16] Department of Chemistry,undefined
[17] School of Science,undefined
[18] Kwansei-Gakuin University,undefined
[19] Uegahara,undefined
[20] Nishinomiya 662–8501,undefined
[21] Japan e-mail; ozaki@kwansei.ac.jp,undefined
来源
Fresenius' Journal of Analytical Chemistry | 1998年 / 362卷
关键词
Cholesterol; Albumin; Human Serum; Relative Standard Deviation; Human Serum Albumin;
D O I
暂无
中图分类号
学科分类号
摘要
Near infrared (NIR) spectra in the 1300– 1850 nm region were measured for control serum solutions containing both albumin and γ-globulin of various concentrations. Partial least squares two (PLS2) regression was applied to the NIR spectra to determine simultaneously the concentrations of both proteins. For albumin, the correlation coefficient (R) of 0.988, the standard error of calibration (SEC) of 1.61 g/L, the standard error of prediction (SEP) of 1.29 g/L, the relative standard deviation (RSD) of 0.026 and the ratio of standard deviation of reference data in prediction to SEP (RPD) of 12.2 were obtained. For γ-globulin, the corresponding values were 0.997, 1.36 g/L, 1.35 g/L, 0.0365 and 8.66, respectively. The regression coefficients (RCs) of PLS factors were compared between albumin and γ-globulin, and the observed differences in the RCs were discussed based upon the differences in the hydration between albumin and γ-globulin. In order to explore the effects of various metabolites such as glucose, and cholesterol on the chemometrics models, the RCs for albumin and γ-globulin in the control serum solutions were also compared with those for albumin and γ-globulin in phosphate buffer solutions previously studied. The results of our experiments show that NIR spectroscopy with the use of PLS2 regression has considerable promise in nondestructive determination of the concentrations of blood serum proteins.
引用
收藏
页码:155 / 161
页数:6
相关论文
共 50 条
[41]   Understanding the thermal stability of human serum proteins with the related near-infrared spectral variables selected by Monte Carlo-uninformative variable elimination [J].
Liu, Xiu-Wei ;
Cui, Xiao-Yu ;
Yu, Xiao-Ming ;
Cai, Wen-Sheng ;
Shao, Xue-Guang .
CHINESE CHEMICAL LETTERS, 2017, 28 (07) :1447-1452
[42]   Raman spectroscopy study of the optical properties of human serum albumin with dye aqueous solution droplet in presence of silver nanoparticles [J].
Konstantinova, E. I. ;
Zyubin, A. U. ;
Slezhkin, V. A. ;
Samusev, I. G. ;
Bryukhanov, V. V. .
NANOPHOTONICS VII, 2018, 10672
[43]   Determination of the Interaction of Arsenic and Human Serum Albumin by Online Microdialysis Coupled to LC with Hydride Generation Atomic Fluorescence Spectroscopy [J].
Jiang, Hong ;
Ding, Jinghua ;
Chang, Pei ;
Chen, Zaixing ;
Sun, Guifan .
CHROMATOGRAPHIA, 2010, 71 (11-12) :1075-1079
[44]   Determination of the Interaction of Arsenic and Human Serum Albumin by Online Microdialysis Coupled to LC with Hydride Generation Atomic Fluorescence Spectroscopy [J].
Hong Jiang ;
Jinghua Ding ;
Pei Chang ;
Zaixing Chen ;
Guifan Sun .
Chromatographia, 2010, 71 :1075-1079
[45]   Net analyte signal-based simultaneous determination of dyes in environmental samples using moving window partial least squares regression with UV-vis spectroscopy [J].
Sahin, Saliha ;
Sariburun, Esra ;
Demir, Cevdet .
ANALYTICAL METHODS, 2009, 1 (03) :208-214
[46]   The binding of CI Acid Red 2 to human serum albumin: Determination of binding mechanism and binding site using fluorescence spectroscopy [J].
Ding, Fei ;
Li, Nan ;
Han, Binyue ;
Liu, Feng ;
Zhang, Li ;
Sun, Ying .
DYES AND PIGMENTS, 2009, 83 (02) :249-257
[47]   Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples [J].
de la Pena, A. Munoz ;
Duran Meras, I. ;
Jimenez Giron, A. ;
Goicoechea, H. C. .
TALANTA, 2007, 72 (04) :1261-1268
[48]   Understanding the thermal stability of human serum proteins with the related near-infrared spectral variables selected by Monte Carlo-uninformative variable elimination [J].
XiuWei Liu ;
XiaoYu Cui ;
XiaoMing Yu ;
WenSheng Cai ;
XueGuang Shao .
ChineseChemicalLetters, 2017, 28 (07) :1447-1452
[49]   Structural changes of human serum albumin immobilized on chromatographic supports:: a high-performance liquid chromatography and Fourier-transform infrared spectroscopy study [J].
Millot, MC ;
Servagent-Noinville, S ;
Taleb, NL ;
Baron, MH ;
Revault, M ;
Sébille, B .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (01) :101-113
[50]   CONFORMATIONAL-CHANGES OF HUMAN SERUM-ALBUMIN INVIVO INDUCED BY FREE FATTY-ACIDS AS STUDIED BY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
LEGAL, JM ;
MANFAIT, M .
BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1041 (03) :257-263