Determination of human serum albumin and γ-globulin in a control serum solution by near-infrared spectroscopy and partial least squares regression

被引:0
|
作者
Koichi Murayama
Keiichi Yamada
Roumiana Tsenkova
Y. Wang
Y. Ozaki
机构
[1] Merchandise Development Laboratory,
[2] Daiken Medical Co.,undefined
[3] Ltd.,undefined
[4] 4–36,undefined
[5] Funaocho-Higashi,undefined
[6] Hamadera,undefined
[7] Sakai 592–8341,undefined
[8] Japan,undefined
[9] Department of Environment Information and Bio-production Engineering,undefined
[10] Faculty of Agriculture,undefined
[11] Kobe University,undefined
[12] Rokkodai,undefined
[13] Nada-ku,undefined
[14] Kobe 657–8501,undefined
[15] Japan,undefined
[16] Department of Chemistry,undefined
[17] School of Science,undefined
[18] Kwansei-Gakuin University,undefined
[19] Uegahara,undefined
[20] Nishinomiya 662–8501,undefined
[21] Japan e-mail; ozaki@kwansei.ac.jp,undefined
来源
Fresenius' Journal of Analytical Chemistry | 1998年 / 362卷
关键词
Cholesterol; Albumin; Human Serum; Relative Standard Deviation; Human Serum Albumin;
D O I
暂无
中图分类号
学科分类号
摘要
Near infrared (NIR) spectra in the 1300– 1850 nm region were measured for control serum solutions containing both albumin and γ-globulin of various concentrations. Partial least squares two (PLS2) regression was applied to the NIR spectra to determine simultaneously the concentrations of both proteins. For albumin, the correlation coefficient (R) of 0.988, the standard error of calibration (SEC) of 1.61 g/L, the standard error of prediction (SEP) of 1.29 g/L, the relative standard deviation (RSD) of 0.026 and the ratio of standard deviation of reference data in prediction to SEP (RPD) of 12.2 were obtained. For γ-globulin, the corresponding values were 0.997, 1.36 g/L, 1.35 g/L, 0.0365 and 8.66, respectively. The regression coefficients (RCs) of PLS factors were compared between albumin and γ-globulin, and the observed differences in the RCs were discussed based upon the differences in the hydration between albumin and γ-globulin. In order to explore the effects of various metabolites such as glucose, and cholesterol on the chemometrics models, the RCs for albumin and γ-globulin in the control serum solutions were also compared with those for albumin and γ-globulin in phosphate buffer solutions previously studied. The results of our experiments show that NIR spectroscopy with the use of PLS2 regression has considerable promise in nondestructive determination of the concentrations of blood serum proteins.
引用
收藏
页码:155 / 161
页数:6
相关论文
共 50 条
  • [1] Near-infrared spectra of serum albumin and γ-globulin and determination of their concentrations in phosphate buffer solutions by partial least squares regression
    Murayama, K
    Yamada, K
    Tsenkova, R
    Wang, Y
    Ozaki, Y
    VIBRATIONAL SPECTROSCOPY, 1998, 18 (01) : 33 - 40
  • [2] Multivariate determination of human serum albumin and γ-globulin in a phosphate buffer solution by near infrared spectroscopy
    Murayama, K
    Yamada, K
    Tsenkova, R
    Wang, Y
    Ozaki, Y
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : 375 - 381
  • [3] Comparison of performance of partial least squares regression, secured principal component regression, and modified secured principal component regression for determination of human serum albumin, γ-globulin and glucose in buffer solutions and in vivo blood glucose quantification by near-infrared spectroscopy
    Li, Bo-Yan
    Kasemsumran, Sumaporn
    Hu, Yun
    Liang, Yi-Zeng
    Ozaki, Yukihiro
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) : 603 - 611
  • [4] Comparison of performance of partial least squares regression, secured principal component regression, and modified secured principal component regression for determination of human serum albumin, γ-globulin and glucose in buffer solutions and in vivo blood glucose quantification by near-infrared spectroscopy
    Bo-Yan Li
    Sumaporn Kasemsumran
    Yun Hu
    Yi-Zeng Liang
    Yukihiro Ozaki
    Analytical and Bioanalytical Chemistry, 2007, 387 : 603 - 611
  • [5] Determination of biochemical parameters in human serum by near-infrared spectroscopy
    Garcia-Garcia, J. L.
    Perez-Guaita, D.
    Ventura-Gayete, J.
    Garrigues, S.
    de la Guardia, M.
    ANALYTICAL METHODS, 2014, 6 (12) : 3982 - 3989
  • [6] Reagentless Near-Infrared Determination Of Cholesterol In Undiluted Human Serum Using Interval Partial Least Square
    Gao, Hongzhi
    Lu, Qipeng
    Huang, Furong
    SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, 2012, 345 : 128 - +
  • [7] Determination of Concentrations of Glucose and Human Serum Albumin in Mixtures in Phosphate-Buffered Solution by Near-Infrared Spectroscopy
    Ogawa, Mitsuhiro
    Yamakoshi, Takehiro
    Motoi, Kosuke
    Nishida, Koji
    Yamakoshi, Yasuhiro
    Yamakoshi, Ken-Ichi
    SENSORS AND MATERIALS, 2012, 24 (06) : 323 - 333
  • [8] Analysis of hydration water around human serum albumin using near-infrared spectroscopy
    Dong, Qin
    Yu, Chen
    Li, Lian
    Nie, Lei
    Zhang, Hui
    Zang, Hengchang
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 138 : 927 - 932
  • [9] A Near Infrared Fluorescent Probe for Sensitive Determination of Human Serum Albumin
    Zeng, Xiaodan
    Ma, Mingshuo
    Zhu, Baocun
    Zhu, Lin
    ANALYTICAL SCIENCES, 2016, 32 (12) : 1291 - 1294
  • [10] A Near Infrared Fluorescent Probe for Sensitive Determination of Human Serum Albumin
    Xiaodan Zeng
    Mingshuo Ma
    Baocun Zhu
    Lin Zhu
    Analytical Sciences, 2016, 32 : 1291 - 1294