Evaluation of new hip prosthesis design with finite element analysis

被引:0
作者
Talip Çelik
Yasin Kişioğlu
机构
[1] Kocaeli University,Department of Biomedical Engineering, Technology Faculty
来源
Australasian Physical & Engineering Sciences in Medicine | 2019年 / 42卷
关键词
Hip prosthesis; Finite element analysis; New hip prosthesis; Computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Cemented and cementless hip prostheses are used in total hip replacement surgery. Short, medium and long term success rates of these hip prostheses are controversial in the literature. Traditional cemented and cementless hip prostheses have advantages and disadvantages affecting the success of the implantation process. In this study, a new design of hip prosthesis is presented considering the advantages and disadvantages of the prostheses. Femur and prostheses were modeled and combined with each other to perform the finite element analysis (FEA). The new design of prosthesis was compared to the conventional prosthesis in terms of mechanical aspects. The evaluation criteria are the maximum von Mises stress and micro-movement of the contact between femur and prosthesis. In conclusion, the new design of prosthesis was found to provide a sufficient amount of primary stability and decreased the risk of stress shielding.
引用
收藏
页码:1033 / 1038
页数:5
相关论文
共 95 条
  • [1] Abdulkarim A(2013)Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials Orthop Rev (Pavia) 5 e8-1766
  • [2] Ellanti P(2012)Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales Lancet 380 1759-2170
  • [3] Motterlini N(2008)Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older J Bone Joint Surg Am 90 2160-41
  • [4] Fahey T(2010)Uncemented and cemented primary total hip arthroplasty in the Swedish hip arthroplasty register evaluation of 170,413 operations Acta Orthop 81 34-1832
  • [5] O'Byrne JM(2012)Twelve-year risk of revision after primary total hip replacement in the US medicare population J Bone Joint Surg 94 1825-1533
  • [6] Smith AJ(2007)Cement mantle fatigue failure in total hip replacement: experimental and computational testing J Biomech 40 1525-303
  • [7] Dieppe P(2000)The fixation of the cemented femoral component—effects of stem stiffness, cement thickness and roughness of the cement-bone surface J Bone Joint Surg Br 82 297-2558
  • [8] Howard PW(2007)Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models J Biomech 40 2552-355
  • [9] Blom AW(1995)Relations of mechanical-properties to density and Ct numbers in human bone Med Eng Phys 17 347-1583
  • [10] Wales NJRE(2007)Static, dynamic and fatigue behavior of newly designed stem shapes for hip prosthesis using finite element analysis Mater Des 28 1577-871