A novel electrochemical immunosensor based on Au nanoparticles and horseradish peroxidase signal amplification for ultrasensitive detection of α-fetoprotein

被引:0
作者
Dingqiang Lu
Qiuda Xu
Guangchang Pang
Fuping Lu
机构
[1] Tianjin University of Science &Technology,College of Biotechnology
[2] Key Laboratory of Industrial Fermentation Microbiology,College of Biotechnology & Food Science
[3] Ministry of Education,undefined
[4] Tianjin University of Commerce,undefined
[5] Tianjin Key Laboratory of Food Biotechnology,undefined
来源
Biomedical Microdevices | 2018年 / 20卷
关键词
α-fetoprotein; Au nanoparticles; Amperometric I-t curve method; Electrochemical immunosensor; Horseradish peroxidase; Membrane potential;
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemical double-layer Au nanoparticle membrane immunosensor was developed using an electrochemical biosensing signal amplification system with Au nanoparticles, thionine, chitosan, and horseradish peroxidase, which was fabricated using double self-adsorption of Au nanoparticle sol followed by anti-α-fetoprotein Balb/c mouse monoclonal antibody adsorption. The AuNPs sol was characterized by spectrum scanning and transmission electron microscopy. The immunosensor was characterized by atomic force microscopy, cyclic voltammetry, and alternating-current impedance during each stage of adsorption and assembly. The amperometric I-t curve method was used to measure α-fetoprotein (AFP) diluted in phosphate buffered saline. The result indicated a wide linear range, and the change rate of steady-current before and after immune response had linear correlation within the range 0.1–104 pg/mL AFP. The current change rate equation was △I = 5.82334 lgC + 37.01195 (R2 = 0.9922). The lowest limit of detection was 0.03 pg/mL (S/N = 3), and the reproducibility of the sensor was good. Additionally, the sensor could be stably stored above phosphate buffered saline at 4 °C for more than 24 days. More importantly, the sensor is label-free, reagentless and low fouling, making it capable of assaying AFP in real serum samples without suffering from significant interference or biofouling.
引用
收藏
相关论文
共 184 条
[1]  
Aydin S(2015)undefined Peptides 72 4-15
[2]  
Ball P(1992)undefined Nature 355 761-766
[3]  
Garwin L(1998)undefined Science 281 2013-2016
[4]  
Bruchez M(2016)undefined Lab Chip 16 409-431
[5]  
Moronne M(1984)undefined Phys. Rev. Lett. 52 1453-1456
[6]  
Gin P(1998)undefined Science 281 2016-2018
[7]  
Weiss S(2012)undefined Lab Chip 12 2118-2134
[8]  
Alivisatos AP(2016)undefined Biosens. Bioelectron. 79 736-741
[9]  
Castiello FR(1973)undefined Nat. Phys. Sci. 241 20-22
[10]  
Heileman K(2008)undefined Sensors Actuators B Chem. 131 455-461