Role of echocardiography in selection of patients for biventricular pacing therapy

被引:2
作者
Agarwal R. [1 ]
Lang R.M. [1 ]
Beshai J.F. [1 ]
机构
[1] University of Chicago Medical Center, Chicago, IL 60637
关键词
Cardiac Resynchronization Therapy; Speckle Tracking; Reverse Remodel; Mechanical Dyssynchrony; Left Ventricular Dyssynchrony;
D O I
10.1007/s11886-009-0049-1
中图分类号
学科分类号
摘要
Cardiac resynchronization therapy (CRT) has demonstrated improved quality of life, New York Heart Association class, left ventricular ejection fraction, and survival in patients with moderate to severe heart failure, left ventricular ejection fraction less than or equal to 35%, and a prolonged QRS duration. QRS duration remains the primary surrogate for mechanical dyssynchrony, defining the pathophysiology of abnormal regional mechanical activation. Studies have demonstrated that 30% to 40% of patients who meet current criteria for CRT are nonresponders. Therefore, there is great interest in the relationship between electrical and mechanical dyssynchrony, and the ability of each alone or together to predict response remains unknown. Echocardiographic approaches have emerged to quantify mechanical dyssynchrony with greater specificity than QRS duration alone. Although these methods are complex, exciting, and highly accurate for predicting response to CRT in single-center studies, they lack widespread applicability and validation to replace current criteria for device implantation. Use of echocardiography to define dyssynchrony and the impact of promising imaging methods for future patient selection for CRT are discussed. © Current Medicine Group, LLC 2009.
引用
收藏
页码:352 / 359
页数:7
相关论文
共 42 条
[1]  
Cazeau S., Leclercq C., Lavergne T., Et al., Multisite Simulation in Cardiomyopathies (MUSTIC) Study Investigators: Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay, N Engl J Med, 344, pp. 873-880, (2001)
[2]  
Abraham W.T., Fisher W.G., Smith A.L., Et al., MIRACLE Study Group: Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure, N Engl J Med, 346, pp. 1845-1853, (2002)
[3]  
Bristow M.R., Saxon L.A., Boehmer J., Et al., Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure (COMPANION) Investigators: Cardiac resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure, N Engl J Med, 350, pp. 2140-2150, (2004)
[4]  
Cleland J.G., Daubert J.C., Erdmann E., Et al., The effect of cardiac resynchronization on morbidity and mortality in heart failure, N Engl J Med, 352, pp. 1539-1549, (2005)
[5]  
Ypenburg C., Van Bommel R.J., Marsan N.A., Et al., Effects of interruption of long-term cardiac resynchronization therapy on left ventricular function and dyssynchrony, Am J Cardiol, 102, pp. 718-721, (2008)
[6]  
Auricchio A., Stellbrink C., Butter C., Et al., Pacing Therapies in Congestive Heart Failure II Study Group, Guidant Heart Failure Research Group: Clinical efficacy of cardiac resynchronization therapy using left ventricular pacing in heart failure patients stratified by severity of ventricular conduction delay, J Am Coll Cardiol, 42, pp. 2109-2116, (2003)
[7]  
Hawkins N.M., Petrie M.C., MacDonald M.R., Et al., Selecting patients for cardiac resynchronization therapy: Electrical or mechanical dyssynchrony?, Eur Heart J, 27, pp. 1270-1281, (2006)
[8]  
Beshai J.F., Khunnawat C., Lin A.C., Mechanical dyssynchrony from the perspective of a cardiac electrophysiologist, Curr Opin Cardiol, 23, pp. 447-451, (2008)
[9]  
Achilli A., Sassara M., Ficili S., Et al., Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and "narrow" QRS, J Am Coll Cardiol, 42, pp. 2117-2124, (2003)
[10]  
Bleeker G.B., Holman E.R., Steendijk P., Et al., Cardiac resynchronization therapy in patients with a narrow QRS complex, J Am Coll Cardiol, 48, pp. 2243-2250, (2006)