Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS

被引:0
作者
R. Iezzi
A. R. Cotroneo
R. Basilico
A. Simeone
M. L. Storto
L. Bonomo
机构
[1] Institute of Radiology,Department of Bioimaging and Radiological Sciences
[2] “A. Gemelli” Hospital,Department of Clinical Science and Bioimaging, Section of Radiology
[3] Catholic University,undefined
[4] University “G. D’Annunzio”,undefined
来源
Abdominal Imaging | 2010年 / 35卷
关键词
Abdominal aortic aneurysm; Computed tomography; Endovascular repair; Endoleaks; Ultrasonography; Contrast-enhanced ultrasonography;
D O I
暂无
中图分类号
学科分类号
摘要
Endovascular repair (EVAR) is playing an increasingly role in the treatment of abdominal aortic aneurysm. A successful procedure depends on the complete sealing of the aneurysm sac from blood flow to achieve general pressure relief and avoid aneurysm rupture, with a shrinkage of the aneurysm sac. The most common complication of EVAR is endoleak that is the persistence of perigraft flow within the aneurysm sac, which has to be considered the major cause of enlargement and rupture of the aneurysm, and the main indication for surgical late conversion. For this reason, strict surveillance of these patients is mandatory for the early detection of endoleaks and the preferred method of follow-up is represented by CT angiography. However, CTA has limitations. The investigation is repeated several times, making radiation exposure a necessary concern. Therefore, it would be useful to have another reliable diagnostic examination during follow-up. Color duplex ultrasound is non-invasive, does not use radiation or contrast medium, is less expensive, easy to perform and widely available. However, this technique obtained poor results in terms of sensitivity in the detection of endoleaks. In the last years, the introduction of ultrasound contrast agents and contrast-specific imaging has, however, rekindled interest in this modality and its potential for replacing of CTA in routine surveillance. The purpose of this review is to highlight the diagnostic value of CEUS in the post-EVAR endoleaks detection.
引用
收藏
页码:106 / 114
页数:8
相关论文
共 105 条
[11]  
Fogarty TJ(1998)Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition AJR Am J Roentgenol 171 329-331
[12]  
Cuypers P(2007)Computer tomography—an increasing source of radiation exposure N Engl J Med 357 2277-2284
[13]  
Buth J(2003)Color-flow duplex ultrasound versus computed tomographic scan in the surveillance of endovascular aneurysm repair J Vasc Surg 38 645-651
[14]  
Harris PL(1998)Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan J Vasc Surg 28 657-663
[15]  
Gevers E(2006)Contrast-enhanced duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique J Vasc Surg 43 259-264
[16]  
Lahey R(2005)Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair J Vasc Surg 41 10-18
[17]  
Gilling-Smith G(2004)Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair Radiology 233 217-225
[18]  
Brennan J(2003)Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance J Endovasc Ther 10 208-217
[19]  
Harris P(2003)Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts J Vasc Surg 37 381-385
[20]  
Golzarian J(1997)Interactions between microbubbles and ultrasound: in vitro and in vivo observations J Am Coll Cardiol 29 1081-1088